Product Details:
|
Product Name: | Sludge Concentration Sensor | Product Model: | OPSS900 |
---|---|---|---|
Measuring Principle: | Infrared Scattering Principle Independent Of Color | Light Source: | 850nm Infrared Light Source |
Measuring Range: | 0~20000mg/L | Resolution: | 1mg/L |
Accuracy: | Less Than 5% Of The Measured Value | Power Supply: | 12VDC, Power Consumption About 50mA |
Work Pressure: | ≤0.4Mpa | Calibration Method: | Activated Sludge Calibration, Diatomite Calibration, Linear Calibration |
Operating Temperature: | 0.0~45.0℃ | Material: | Stainless Steel+POM |
Dimensions: | Diameter: 52mm, Length: 195mm | Protection Level: | IP68 |
Weight: | Approximately 700g (without Cable) | Cable: | 3 Meters (customized) |
Highlight: | 52mm Suspended Solid Analyzer,195mm sludge density meter,195mm Suspended Solid Analyzer |
sludge concentration sensor 180 degree Infrared scattering for sewage plants
About DRFN’s Sludge Concentration Sensor
Sludge concentration is the degree of hindrance of the suspended substances in the water to the transmission of light. The water contains mud, silt, fine organic matter and other microorganisms and colloids that can make the water appear turbid.
According to the scattered light intensity of suspended particles in the water sample, OPSS900 infrared sludge concentration sensor uses 180 degree infrared beam method to measure the suspended solids value of the sample.
The sensor uses a near-infrared LED as the light source. The advantage of this is that the color in the sample does not affect the measurement result.
Advantages Of Sludge Concentration Sensor
Selected stainless steel and POM material, durable and long life
Applications Of Sludge Concentration Sensor
Online monitoring of the sludge concentration in each process of the sewage treatment plant;
Online monitoring of suspended solids (sludge concentration) in various industrial production processes, such as water and wastewater treatment processes.
Technical Parameter
Product Name | Sludge Concentration Sensor |
Product Model | OPSS900 |
Measuring Principle | Infrared scattering principle independent of color |
Light Source | 850nm infrared light source |
Measuring Range | 0~20000mg/L |
Resolution | 1mg/L |
Accuracy | Less than 5% of the measured value |
Power Supply | 12VDC, power consumption about 50mA |
Work Pressure | ≤0.4Mpa |
Calibration Method | Activated sludge calibration, diatomite calibration, linear calibration |
Operating Temperature | 0.0~45.0℃ |
Material | stainless steel+POM |
Dimensions | 52mm in diameter, 195mm in length |
Protection Level | IP68 |
Weight | Approximately 700g (without cable) |
Cable | 3 meters, length can be customized |
Contact Person: Ms. Yuki Fu
Tel: +8615716217387