Product Details:
|
Product Name: | Suspended Solids Sensor | Measuring Principle: | Infrared Scattered Light Method |
---|---|---|---|
Measuring Range: | 0.01-45g/L | Accuracy: | <5% Of The Measured Value |
Resolution: | 0.01g/L | Response Time: | T90<60s |
Calibration: | Factor Calibration, Multi-point Calibration | Communication: | RS485, Modbus-RTU |
Work Pressure: | ≤4bar | Work Temp: | 0~50℃ (does Not Freeze) |
Storage Temp: | -10~60℃ | Power Supply: | 12V DC |
Dimensions: | D65mm * L270mm | Installation: | Special 90° Installation Accessories |
Material: | PVC(Standard)SUS316L/ T I(option) / POM | Protection Grade: | IP68 |
Brush: | Automatic Brush(Optional) | ||
Highlight: | Suspended Solids Sensor With Brush,12V DC Suspended Solids Analyzer,RS485 Suspended Solids Monitor |
45g/L RS485 Suspended Solids Sensor with brush for Waste Treatment
Fluorescent Sludge Concentration Sensor MLSS31 is a technology commonly used to measure sludge concentration in water bodies. It uses the fluorescence characteristics of specific substances in sludge for concentration analysis. Compared with other sensing technologies, fluorescence sensors have some advantages in specific application scenarios:
High Sensitivity: Fluorescence sensors are very sensitive to changes in the concentration of target substances and can provide accurate measurement results even in the lower concentration range.
Specificity: Fluorescent sensors are usually based on the interaction of specific fluorescent markers with target substances, so they have high specificity and can distinguish target substances from other impurities.
Real-time: Fluorescence sensors provide real-time measurement data, and results can be obtained within seconds to minutes, and are suitable for scenarios that require rapid monitoring and response.
Environmental adaptability: Fluorescence sensors have strong adaptability to environmental changes and can work stably under different water quality conditions.
Low cost: Relative to some other high-cost sensing technologies, fluorometric sensors are relatively inexpensive to manufacture, making them suitable for large-scale deployment and monitoring.
Wide application: Fluorescence sensors can be used in many fields such as wastewater treatment, environmental monitoring, and biological research, and have broad application prospects.
Specification:
Model |
MLSS300 (no wiper) MLSS301 (with wiper) |
MLSS310 (no wiper) MLSS311 (with wiper) |
MLSS320 (no wiper) MLSS321 (with wiper) |
Measuring Principle | Infrared scattered light method | ||
Measuring Range | 0.01-20g/L | 0.01-45g/L | 0.01-120g/L |
Accuracy | Less than 5% of the measured value | ||
Resolution | 0.01g/L | ||
Response Time | T90<60s | ||
Calibration | Factor calibration, multi-point calibration | ||
Communication | RS485, Modbus-RTU | ||
Work Pressure | ≤4bar | ||
Work Temp | 0~50℃ (does not freeze) | ||
Storage Temp | -10~60℃ | ||
Flow Rate | Not dependent | ||
Power Supply | 12V DC | ||
Dimensions | Diameter 65mm * Length 270mm | ||
Installation | Horizontal installation, special 90° installation accessories | ||
Material | Body: PVC(Standard)SUS316L/ T i(option) / POM | ||
Protection Grade | IP68 | ||
Cable | Standard 10 meters | ||
Weight | 800g | ||
Power Consumption | 1.5W |
Please click the user manual of Suspended Solids sensor here:
Brief introduction:
Aplication:
◇Soil remediation and pollution control
◇Bioenergy and Resource Recovery
◇Industrial Waste Treatment
◇Architecture and Construction
◇Academic Research
◇Wastewater treatment plant
◇ Waterworks
◇ Surface water
◇Semiconductor
◇Environmental water treatment
◇ Paper industry
◇ Mining
◇ Metallurgical Electronics
Contact Person: Yuki Fu
Tel: +8615716217387