Product Details:
|
Product Name: | COD Meter | Measuring Principle: | UV254 Ultraviolet Absorption |
---|---|---|---|
Measuring Range(COD): | 0.75~370mg/L | Measuring Range(TOC): | 0.3 ~150mg/L |
Measuring Range(TU): | 0~300 NTU | Operating Temperature: | +5 ~ 45℃ |
Working Pressure: | 1Bar | Protection Grade: | IP68 |
Response Time: | T90 Max. 10s | Cleaning Method: | Rubber Scraper |
Highlight: | Digital COD Sensor,IP68 Protection COD Sensor,Turbidity COD Analyzers |
Digital BOD, TOC ,Turbidity COD Sensor For Water Treatment Plant Measuring
Many organic substances dissolved in water absorb ultraviolet light. Therefore, by measuring the degree of absorption of 254nm wavelength ultraviolet light by these organic substances, the content of dissolved organic pollutants in water can be accurately measured.
Specification:
Model | CODuv351 |
Measuring Principle | UV254 ultraviolet absorption method |
Measuring Range(COD) | 0.75~370mg/L |
Resolution(COD) | 0.01mg/L |
Accuracy(COD) | ±2% or ±2.5mg/L, take the larger one |
Measuring Range(TOC) | 0.3 ~150mg/L |
Accuracy(TOC) | ±2% or ±2.5mg/L, take the larger one |
Resolution(TOC) | 0.1mg/L |
Measuring Range(TU) | 0~300 NTU |
Accuracy(TU) | 3% or 0.2NTU, take the larger one |
Resolution(TU) | 0.1NTU |
Operating Temperature | +5 ~ 45℃ |
Calibration | 2-point calibration |
Protection Grade | IP68 |
Working Pressure | 1Bar |
Response Time | T90 max. 10s |
Flow Rate | < 3 m/s |
Cleaning Method | Rubber scraper |
Power | 12V 15mA (normal), 200mA (max. when cleaning) |
Output | RS485, Modbus RTU protocol |
Dimension | Diameter 50mm, length 215mm |
Cable Length | 10m(custom) |
Shell Material | POM and 316L |
Please click the user manual of RS485 COD sensor here:
Brief introduction:
● Use UV254 nano-ultraviolet absorption measurement method, require no consumable;
● Use two light sources, 254nm and 365nm UV reference light;
● Automatically eliminate the interference of suspended solids and compensate for the interference of turbidity;
● Can measure parameters such as COD, TOC, turbidity and temperature;
● Drop-in installation, no need to digest the tested sample, fast analysis speed, real-time response, no need to wait;
● RS485 digital interface, standard Modbus communication protocol, support access to standard industrial control system;
● Have excellent repeatability and stability, and is not easily affected by ambient light;
● integrated self-cleaning brush, small size and convenient to install, continuously monitor water quality online to prevent biological attachment and reduce the frequency of maintenance
Aplication:
◇ Surface water
◇ Process water
◇ Sewage treatment plant
◇ Industrial wastewater
◇ Drinking water
◇ River
FAQ
1. Does the COD meter can detect COD BOD TOCTurbidity and temperature?
Our COD sensor can detetect COD BOD Turbidity and temp.
2.How long is your delivery time?
A: Generally it is 3 days if the goods are in stock. or within 20 days if the goods are not in stock, it is according to quantity.
Contact Person: Yuki Fu
Tel: +8615716217387