Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE
Model Number: ADS2-U3-WP7
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable

IP66 Disinfection Hydrogen Peroxide Analyzer Modbus RTU For Drinking Water

Description
Product Name: Hydrogen Peroxide Analyzer Product Model: ADS2-U3-WP7
Software Version: DRFN H2O2 Analysis Software V1.0 Relay Control: 2 SPST Relays
Communication: RS485 Protection Grade: IP66
Operating Environment: 0~60℃ Material: Enhanced ABS
Dimension: 144*144*120mm Mounting Method: Wall, Pipe Clamping, Panel
Weight: 800g Power Consumption: 12W
High Light:

IP66 hydrogen peroxide analyzer

,

h2o2 concentration meter

,

IP66 hydrogen peroxide analyzer

 

IP66 Disinfection Hydrogen Peroxide Analyzer Modbus RTU For Drinking Water

 

 

Hydrogen peroxide(H2O2) is a strong oxidant, which is widely used in the disinfection of water supply systems, the treatment of industrial wastewater, and the treatment of river pollution. As a disinfectant, hydrogen peroxide has many advantages in the disinfection of drinking water, such as safety, no secondary pollution, and environmental protection. However, excessive hydrogen peroxide can still cause harm to the human body, so it is very necessary to accurately measure and effectively control the concentration of hydrogen peroxide in the water.

 

Daruifuno’s hydrogen peroxide analyzer is a single parameter instrument for the measurement of hydrogen peroxide.

 

 

Advantages Of The Hydrogen Peroxide Analyzer

 

  • IP66 protection grade
  • RS485 interface, Modbus RTU communication protocol
  • 128*64 black and white graphic dot matrix LCD screen
  • Record user's maintenance details of the equipment
  • Support a variety of installation methods
  • Provide wide-voltage AC or DC power supply mode
  • Clock and historical data recording functions

 

Applications Of The Hydrogen Peroxide Analyzer

 

Drinking water, industrial wastewater, water supply system, urban sewage treatment

 

 

Parameters Of The Hydrogen Peroxide Analyzer

 

Product Name hydrogen peroxide analyzer
Product Model

ADS2-U3-WP7

Software Version

DRFN H2O2 Analysis software V1.0

Display Range

0.00~200.00mg/L

Resolution

0.001mg/L

Accuracy

Better than 0.15% of the measuring range

Stability

0.05% of the measuring range every 24 hours, no accumulation

Repeatability

Better than 0.1% of the measuring range

Relay Control

2 settable SPST relays, the max. load 3A/250VAC

Sensor Self-diagnosis

screen image and buzzer prompt

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data

Protection Grade

IP66

Operating Environment

0~60℃, relative humidity less than 95%

Storage Environment

-20~70℃, relative humidity less than 55%

Shell Material

Enhanced ABS

Dimensions

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel installation

Power Supply

18~36V DC or 100~240V AC

Weight

800g

Power Consumption 12W

 
IP66 Disinfection Hydrogen Peroxide Analyzer Modbus RTU For Drinking Water 0
 
Matching Hydrogen Peroxide Sensor Parameters

  • PH range: 2~11
  • Pressure range: 0~1 bar, no pressure surges and/or fluctuations
  • Temperature range: 0~45 ℃ (no ice crystals in water)
  • Response time: T90 about 5~10 min
  • Flow rate: approx. 30 l/h, low flow-dependence
  • Sensor with automatic temperature compensation
  • Material: PVC-U, stainless steel 1.4571
  • Calibration: at the controller, analytical determination by DPD-method

 

Type

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number
WP7MA-CC 0.0~200.0 0.1 4~20 mA

12~30 VDC

RL 50Ω~900Ω

3326081
WP7MA-D 0.0~500.0 0.1 3326075
WP7MA-M 0.0~1000 1 3326099
WP7MA-MM 0~2000 1 3326074
WP7MA-XM 0~10000 10 3326072
WP7MA-CC-M12 0.0~200.0 0.1 4~20 mA

12~30 VDC

RL 50Ω~900Ω

3226100
WP7MA-D-M12 0.0~500.0 0.1 3226101
WP7MA-M-M12 0.0~1000 1 3226102
WP7MA-MM-M12 0~2000 1 3226103
WP7MA-XM-M12 0~10000 10 3226104
 

 
 
 