Product Details:
|
Product Name: | Chlorine Dioxide Analyzer | Product Model: | ADS2-U3A-CD4.2 |
---|---|---|---|
Software Version: | DRFN Chlorine Dioxide Analysis Software V1.0 | Display Range: | 0.00-200.00mg/L |
Protection Grade: | IP66 | Size: | 144*144*120mm |
Power Supply: | 100~240V AC | Weight: | 800g |
Power Consumption: | 12W | Mounting Method: | Wall Mount, Pipe Clamping, Panel |
High Light: | 1pH Water Quality Transmitter,12pH Chlorine Dioxide Analyzer,12W Water Quality Transmitter |
1 ~ 12pH Chlorine Dioxide Analyzer Measuring Of Disinfectant Concentration IP66
Introduction
Chlorine dioxide disinfectant is an internationally recognized high-efficiency disinfectant. It can kill all microorganisms and will not make bacteria resistant to drugs. The ADS2-U3A-CD4.2 chlorine dioxide analyzer is a single-parameter instrument. It is compatible with DRFN's membrane-covered chlorine dioxide sensors.
Advantages Of Chlorine Dioxide Analyzer
1. Abundant output meets monitoring, control and remote data transmission at the same time.
2. Equipped with a two-wire RS485 interface, the communication protocol is MODBUS RTU. The chlorine dioxide analyzer supports JSON text data format.
3. All the configuration entered by the user is kept indefinitely, even if there is no power, the data will not be lost.
4. 128*64 black and white graphic dot matrix screen, and the display backlight provides always on and energy-saving mode selection.
5. It has time and historical data recording functions to meet higher data management requirements.
Parameters Of Chlorine Dioxide Analyzer
Product Name | Chlorine dioxide analyzer |
Product Model |
ADS2-U3A-CD4.2 |
Software Version |
DRFN chlorine dioxide Analysis software V1.0 |
Display Range |
0.00-200.00mg/L |
Resolution |
0.001 mg/L |
Accuracy |
Better than 0.15% of the measuring range |
Stability |
0.05% of the measuring range every 24 hours, no accumulation |
Repeatability |
Better than 0.1% of the measuring range |
Relay Control |
2 settable SPST relays, the max. load 3A/250VAC |
Sensor Self-diagnosis |
screen image and buzzer prompt |
Analog Current Output |
2 settable 0/4~20mA active current loop output max. load 1000Ω |
Communication Method |
MODBUS RTU; support JSON text data format |
Display Screen |
128*64 LCD |
Time History/Data Record |
Year/month/day/hour/min/second, record 14000 historical data |
Protection Grade |
IP66 |
Operating Environment |
0~60℃, relative humidity less than 95% |
Storage Environment |
-20~70℃, relative humidity less than 55% |
Shell Material |
Enhanced ABS |
Dimensions |
144*144*120mm (hole size 138*138 mm) |
Mounting Method |
Wall mounting, pipe clamping, panel installation |
Power Supply |
100~240V AC |
Weight |
800g |
Power Consumption | 12W |
The Matching Chlorine Dioxide Sensors Recommendation
Pressure range: 0~1 bar
Temperature range: 0~45℃
Integrated automatic temperature compensation
Response time: T90 about 15 s
Flow rate: about 30 l/h, low flow-dependence
Shaft length: standard 175 mm, and up to 220 mm in length (mA-Version)
Connection: for mA-version 2-pole terminal, M12 male
Item number | Type | Measuring range: ppm |
Resolution: ppm |
Output signal | Power supply |
3326480 | CD4.2MA0.5 | 0.005~0.500 | 0.001 | 4~20 mA | 12~30 VDC RL 50~900Ω |
3326481 | CD4.2MA2 | 0.05~2.00 | 0.01 | ||
3326482 | CD4.2MA5 | 0.05~5.00 | 0.01 | ||
3326483 | CD4.2MA10 | 0.05~10.00 | 0.01 | ||
3326490 | CD4.2MA0.5-M12 | 0.005~0.500 | 0.001 | 4~20 mA | 12~30 VDC RL 50~900Ω |
3326491 | CD4.2MA2-M12 | 0.05~2.00 | 0.01 | ||
3326492 | CD4.2MA5-M12 | 0.05~5.00 | 0.01 | ||
3326493 | CD4.2MA10-M12 | 0.05~10.00 | 0.01 |
Contact Person: Ms. Yuki Fu
Tel: +8615716217387