logo
Home ProductsConductivity Analyzer

DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost

DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost
DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost

Large Image :  DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost

Product Details:
Place of Origin: China
Brand Name: DEC
Certification: CE, RoHS
Model Number: DEC890
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD 120-320 / Piece
Packaging Details: Shock-proof foam insert with corrugated export carton, 1 piece per box
Delivery Time: 3-7 working days for stock, 15-25 days for bulk production
Payment Terms: T/T, L/C, Western Union, PayPal
Supply Ability: 2000 Pieces per Month

DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost

Description
Measuring Principle: Graphite Two-electrode Measuring Range: 0~20uS/cm To 2~10mS/cm
Resolution: 0.01uS/cm Accuracy: +/-1% Of Range
Temperature Compensation: 0~50C Automatic Or Manual Operating Temperature: 0~50C
Working Pressure: 0~1 Bar Waterproof Level: IP68
Power Supply: DC 9~36V Power Consumption: About 0.2W
Communication: RS485 Modbus-RTU Housing Material: Stainless Steel 316 And POM
Process Connection: 1 Inch NPT Both Ends Cable Length: 10m Standard, Customizable
Application: Low Maintenance Multi-point Conductivity Monitoring
Highlight:

Digital Conductivity Probe Stainless Steel

,

Replaceable Measuring Head Conductivity Probe

,

POM Housing Conductivity Analyzer

DEC890 Digital Conductivity Probe Replaceable Measuring Head Stainless Steel POM Housing Low Maintenance Cost

Most conductivity probes are scrapped when the electrode ages, because the cell and the electronics are potted into one body. The DEC890 separates them: the measuring head is a replaceable module, so when the cell eventually wears or is damaged by an accidental impact, maintenance staff swap the head instead of replacing the whole instrument. For a plant running dozens of monitoring points, that single design decision changes the maintenance budget from a recurring capital expense into a small consumable line item.

Product Overview

The replaceable head concept also shortens downtime. A spare head can be kept on the shelf, fitted in minutes with the existing cable and mount, and the probe is back in service before the next shift. Because the electronics, cable and process connection are reused, the total cost of ownership over a five year horizon is materially lower than with a sealed single-piece probe, and the process connection does not have to be re-engineered every time the cell is renewed.

Key Advantages

  1. Replaceable measuring head renews the sensing element without replacing the body, cable or process connection.
  2. Stainless steel 316 and POM housing with IP68 sealing suits continuous immersion and wash-down duty.
  3. Graphite two-electrode cell resists polarisation, so accuracy is retained across the whole 0~20 uS/cm to 10 mS/cm span.
  4. Up to five calibration points plus offset and factor correction allow traceable recalibration after a head swap.
  5. RS485 Modbus-RTU with isolated power and communication eliminates ground loop noise in electrically noisy plants.
  6. Spare heads can be stocked economically, cutting lead time for breakdown repair from weeks to minutes.
  7. Standard 10 m shielded cable, 1 inch NPT mounting and M16 connector keep spares and fittings common across the plant.

Technical Specifications

Measuring principleGraphite two-electrode measurement principle
Measuring range0~20 µS/cm, 20~200 µS/cm, 200~2000 µS/cm, 2~10 mS/cm
Resolution0.01 µS/cm, 0.1 µS/cm, 1 µS/cm; temperature 0.1 °C
Accuracy±1% of the measuring range
Temperature compensation0~50 °C, automatic or manual
Calibration methodOffset calibration, factor calibration, multi-point calibration (up to 5 points)
Operating temperature0 to 50 °C
Working pressure0~1 Bar
Waterproof levelIP68
Power supplyDC 9~36 V, about 0.2 W
Electrical isolationPower supply and communication isolated
CommunicationRS485 Modbus-RTU, address 17, 9600 bps, no parity, 1 stop bit
Housing materialStainless steel 316 and POM
DimensionsDiameter 37 mm, total length about 261 mm
Process connection1 inch NPT thread at both ends
CableStandard 10 m shielded cable, customizable
ConnectorM16
Serviceable partsMeasuring head replaceable on site
Seal maintenance intervalEvery 2 years

Applications

  • Multi-point water quality networks with dozens of installed probes
  • Municipal wastewater plants with aggressive or abrasive media
  • Industrial effluent monitoring where probes suffer accidental damage
  • Surface water and reservoir stations requiring long unattended service
  • Mining and metallurgy process water with high solids loading
  • Remote monitoring stations where site visits are expensive

Installation, Wiring and Maintenance

Mount the sensor where the flow is stable and bubbles are not easily generated, or submerge it with the measuring front end facing the flowing water. The cable must never be routed in the same conduit as power lines, otherwise measurement interference or cable damage may occur. Wiring is simple: red is power positive (V+), black is power negative (V-), white is RS485 A (AS) and green is RS485 B (BS); the aviation plug version requires no field wiring at all. Keep the electrode surface free of oil and grease, rinse with clean water for routine cleaning, and soak in a light detergent or weak acid for 15 minutes when fouling is heavy. Never wipe the electrode with a hard object, otherwise the sensor must be recalibrated.

FAQ

Q1. What exactly is replaceable?

A: The measuring head, meaning the graphite cell assembly. The housing, cable, electronics and process connection stay in place and are reused.

Q2. How long does a head replacement take?

A: Typically a few minutes with basic tools. After fitting, a two-point calibration restores traceable accuracy; a reset to factory calibration is also supported.

Q3. Does a new head require full multi-point calibration?

A: Not always. Two-point calibration with offset and factor values is normally sufficient. Use multi-point calibration with 84, 146, 1413 and 12880 uS/cm standards if the deviation is large.

Q4. Is the probe still IP68 after a head swap?

A: Yes, provided the head is seated correctly and the seal is in good condition. Seal maintenance is recommended every two years.

Q5. Can I keep spare heads in stock long term?

A: Yes. Heads are compact, do not degrade in storage and can be stocked economically, which is the main reason plants standardise on this design.

Q6. What output does the probe provide?

A: RS485 Modbus-RTU, default address 17 at 9600 bps, no parity, 1 stop bit, with 4-byte floating point measurement data.

Ordering Information

Every unit is supplied with a shock-proof foam insert, export carton, 10 m shielded cable and a printed user manual. Cable length, connector type, thread specification, measuring range configuration and private label packaging can be customized. Please confirm the medium, expected conductivity span and mounting method when ordering, and our engineers will pre-configure the register settings before shipment. Technical support covers commissioning, Modbus register mapping and calibration training.

Tell us your medium and range, and we will send a ready-to-install configuration and quotation within one working day.

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Ms. Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)