Product Details:
|
| Product Model: | DEC790 | Output: | RS485 MODBUS-RTU |
|---|---|---|---|
| Power Consumption: | About 0.2W | Power Supply: | 9~24VDC |
| Default Address: | 17 | Baud Rate: | 9600, No Parity, 1 Stop Bit |
| Data Format: | 4 Byte Float, Little Endian Byte Swap | Conductivity Range: | 0~20uS/cm To 2~10mS/cm |
| TDS Range: | 0~5g/L | Salinity Range: | 0~5ppt |
| Protection Grade: | IP68 | Working Pressure: | <=6 Bar |
| Shell Material: | PPS | Cable: | 5m Standard, 30m Optional |
| Highlight: | RS485 Modbus Conductivity Transmitter,0.2W Low Power EC Probe,Solar Powered Water EC Sensor |
||
The DEC790 is a digital conductivity transmitter built for system integrators, OEM skid builders and remote monitoring projects. There is no local display to configure and no analog loop to trim: the probe is polled over RS485 MODBUS-RTU, returns conductivity, TDS, salinity and temperature as floating point registers, and can be commissioned from the PLC or the gateway in a few minutes. Factory defaults are Modbus address 17, 9600 bps, no parity and one stop bit, and every parameter can be changed through the register map.
Power consumption is the detail integrators notice first: about 0.2 W from a 9~24 VDC supply. That is low enough to run the probe from a small solar panel and battery, or from the 24 VDC rail of a telemetry cabinet, without a dedicated power supply. Several probes can share one bus and one power rail, provided each is given a unique Modbus address before installation.
The measurement cell is a graphite two-electrode design with four ranges from 0~20 µS/cm to 2~10 mS/cm, ±1.0% FS accuracy and automatic temperature compensation. Everything is packaged in a 35 mm PPS body rated IP68 with 1 inch NPT threads at both ends, so the same probe can be used in a skid, a pipe tee, a float assembly or a stainless flow-through housing. Measuring data is transmitted as 4 byte floating point values in little endian byte swapped order, which is the format most PLC Modbus libraries expect once the word order is set.
Most conductivity projects fail in the integration phase rather than the sensor phase: analog scaling is misconfigured, the cable picks up noise from a variable frequency drive, or the transmitter cannot be addressed on an existing bus. The DEC790 removes those failure modes. The value is already linearised and temperature compensated inside the probe, the communication is digital, and the register map is documented in the user manual with the exact addresses for conductivity, TDS, salinity and temperature.
Commissioning steps are short: wire red to V+, black to V-, white to RS485 A and green to RS485 B, set the master to 9600 8N1, read the register block, and confirm the float word order. If the value looks implausible, the word order is the first thing to check. For multi probe installations, assign addresses one at a time so that no two sensors share address 17.
Four wires are required: red is V+ power positive, black is V- power negative, white is RS485 data A(+) and green is RS485 data B(-). The cable enters the PPS body through an M16 gland. Default communication parameters are address 17, baud rate 9600, no parity, one stop bit; all can be modified through the register map described in the user manual. Measurement values are 4 byte floating point numbers in little endian byte swapped order, so the Modbus master must be configured with the matching word order. Calibration values, deviation, factor and temperature correction are also written through standard Modbus function codes, which means the whole commissioning sequence can be scripted from the control system instead of being performed with a handheld configurator.
Maintenance is limited to a monthly visual inspection and a monthly calibration check, with the interval extended once the drift trend is known. Cleaning requires only shaking the probe in clean water; for heavy deposits, soak the measuring section in a mild detergent or weak acid for 15 minutes and rinse with distilled water. Do not wipe or scrape the graphite surface. If a replacement is needed, the measuring module is changed in the field and the Modbus address, cable and mounting stay untouched, so no re-addressing work is required at the gateway.
| Product Model | DEC790 |
|---|---|
| Measuring Principle | Graphite two-electrode measurement |
| Conductivity Range | 0~20 µS/cm, 20~200 µS/cm, 200~2000 µS/cm, 2~10 mS/cm |
| TDS Range | 0~5 g/L |
| Salinity Range | 0~5 ppt |
| Temperature Range | 0.0~50.0 °C |
| Resolution | 0.01 µS/cm |
| Accuracy | ±1.0% FS |
| Temperature Compensation | Automatic temperature compensation |
| Calibration Method | Deviation correction, factor correction, multi-point calibration (up to 5 points) |
| Working Temperature | 0~50 °C |
| Working Pressure | ≤6 bar |
| Protection Grade | IP68 |
| Power Supply | 9~24 VDC |
| Power Consumption | About 0.2 W |
| Communication | RS485 MODBUS-RTU, default address 17, 9600 bps, no parity, 1 stop bit |
| Shell Material | PPS |
| Dimension | Diameter 35 mm, total length 230 mm |
| Installation Size | 1 inch NPT thread at both ends |
| Weight | About 150 g without cable |
| Cable | 5 m standard, length customizable |
| Connection Method | M16 cable gland |
| Data Format | 4 byte float, little endian byte swap |
| Register Map | Documented in user manual appendix A |
| Wiring | Red V+, Black V-, White RS485 A, Green RS485 B |
A: Address 17, baud rate 9600, no parity and one stop bit. The address and baud rate can be changed through the Modbus register map, which is documented in the user manual appendix.
A: Measurements are transmitted as 4 byte floating point numbers in little endian byte swapped order. Configure the master with the matching word order, otherwise the value will look implausible.
A: Multiple probes can share one RS485 bus and one 9~24 VDC rail, as long as every probe has a unique Modbus address. Change the address of the second probe before it is connected.
A: Yes. At roughly 0.2 W the probe can run from a small panel and battery, which is why it is often chosen for remote outfalls, buoys and unmanned stations.
A: No. Temperature is measured inside the probe, temperature compensation is applied internally, and temperature is available as its own Modbus register.
A: Yes. OEM labelling and customised cable lengths are available for volume projects. Please include quantity, cable length and branding requirements in the enquiry.