Product Details:
|
| Product Name: | Online Conductivity Analyzer | Product Model: | AEC1-T1 T2 |
|---|---|---|---|
| Calibration Method: | Deviation & Factor; 1-5 Point Linear Calibration | Conductivity Range: | 0-20 MS/cm, Resolution 0.001 US/cm |
| Accuracy: | Conductivity +/-1% FS; Temp +/-0.5 C | Temp Compensation: | NTC10K / PT1000 Automatic Or Manual, Coefficient Settable |
| TDS Coefficient: | TDS = Conductivity X Coefficient | Relay Control: | Two SPST Relays, 3A 250V AC |
| Analog Output: | Two Active 4-20mA Or 0-20mA, Max 1000 Ohm | Communication: | T1: Without T2: With RS485, Modbus RTU |
| Display Screen: | 3.2 Inch Graphic LCD | Protection Grade: | IP66 |
| Power Supply: | 100-240VAC Or 18-36VDC, 3W Max | Mounting Method: | Panel Mounting |
| Dimension: | 100x100x120 Mm | ||
| Highlight: | 1-5 Point Linear Calibration,NTC10K PT1000 Temp Compensation,Deviation and Factor Calibration |
||
Accurate conductivity data starts with accurate calibration. The AEC1-T1 T2 online conductivity analyzer offers both deviation & factor correction and 1~5 point linear calibration, giving users the flexibility to match the instrument precisely to their water samples. After the electrode is connected, the actual cell constant is entered first, then the measurement can be fine-tuned using the EC offset and EC factor, or calibrated against up to five known samples sorted from low to high conductivity.
Because conductivity varies with temperature, the analyzer includes a configurable temperature compensation coefficient and displays every reading referenced to 25 ℃. A separate TDS coefficient allows the meter to convert conductivity into TDS (ppm) according to the user's requirement. With accuracy of ±1% FS for conductivity and ±0.5 ℃ for temperature, plus resolution down to 0.001 µS/cm, the instrument is well suited to demanding pure-water and process-water duties.
The 3.2 inch graphic LCD shows the measurement type, value, unit, relay state, cell constant and current outputs, while NTC10K/PT1000 automatic or manual temperature compensation keeps results stable across -10~+150 ℃. Two SPST relays, two active 4~20mA outputs and an RS485 Modbus RTU interface complete a precise, easy-to-calibrate conductivity measurement solution.
| Parameter | Specification |
|---|---|
| Product Model | AEC1-T1 T2 |
| Calibration Method | Deviation & factor; 1~5 point linear calibration |
| Cell Constant | User-entered actual K constant |
| Correction Formula | EC value = original × EC factor + EC offset |
| Conductivity Range | 0~20 mS/cm; resolution 0.001 µS/cm |
| Accuracy | Conductivity ±1% FS; Temp. ±0.5 ℃ |
| Temp Compensation | NTC10K / PT1000 automatic or manual, coefficient settable |
| TDS Coefficient | TDS = conductivity (µS/cm) × coefficient |
| Other Ranges | Resistivity 0~18 MΩ·cm; TDS 0~10000 ppm; Salinity 0~15 ppt |
| Display Screen | 3.2 inch graphic LCD |
| Communication | T1: Without T2: With RS485, Modbus RTU |
| Relay / Analog | Two SPST relays (3A 250V AC); two active 4~20mA outputs |
| Power Supply | 100~240VAC or 18~36VDC, 3W Max |
| Protection Grade | IP66 |
| Mounting / Dimension | Panel mounting, 100×100×120 mm, ~500 g |
The analyzer supports deviation & factor correction and 1~5 point linear calibration using known water samples.
Prepare 1~5 samples with known conductivity, sort them from low to high, and calibrate from the first point in order, cleaning and drying the electrode between samples.
Conductivity depends on temperature, so the meter converts readings to a 25 ℃ reference using the settable compensation coefficient.
Yes. Set the TDS coefficient and switch the display to TDS; the value is derived from conductivity multiplied by the coefficient.
Conductivity accuracy is ±1% FS and temperature accuracy is ±0.5 ℃, with resolution down to 0.001 µS/cm.
Ask Daruifuno about calibration solutions, electrodes and controller bundles — contact us today.