Product Details:
|
| Product Name: | Online Conductivity Analyzer | Product Model: | AEC1-T1 T2 |
|---|---|---|---|
| Measurement Method: | 2-electrode | Conductivity Range: | 0-20 MS/cm, Resolution 0.001 US/cm |
| Resistivity Range: | 0-18 MOhm.cm, Resolution 0.001 MOhm.cm | TDS Range: | 0-10000 Ppm, Resolution 0.001 Ppm |
| Salinity Range: | 0-15 Ppt, Resolution 0.001 Ppt | Temperature Range: | -10 To 150 C, Resolution 0.1 C |
| Accuracy: | Conductivity +/-1% FS; Temp +/-0.5 C | Temp Compensation: | NTC10K / PT1000 Automatic Or Manual |
| Relay Control: | Two SPST Relays, 3A 250V AC | Analog Output: | Two Active 4-20mA Or 0-20mA, Max 1000 Ohm |
| Communication: | T1 Without; T2 With RS485, Modbus RTU | Protection Grade: | IP66 |
| Power Supply: | 100-240VAC Or 18-36VDC, 3W Max | Mounting Method: | Panel Mounting |
| Dimension: | 100x100x120 Mm | ||
| Highlight: | 4-in-1 Conductivity Analyzer,TDS Salinity Resistivity Meter,0-20mS cm Conductivity Range |
||
The AEC1-T1 T2 online conductivity analyzer is a continuous-analysis instrument built on a reliable 2-electrode measurement method for conductivity monitoring and control. One compact controller reads four water-quality parameters — conductivity, resistivity, TDS and salinity — plus temperature, switching between them at the touch of a button so operators can monitor an entire process from a single panel device.
With a wide conductivity range of 0~20 mS/cm and ultra-fine resolution down to 0.001 µS/cm, the analyzer suits everything from ultrapure water to concentrated brine. It also measures resistivity (0~18 MΩ·cm), TDS (0~10000 ppm) and salinity (0~15 ppt), each with its own fine resolution. Accuracy of ±1% FS for conductivity and ±0.5 °C for temperature keeps readings dependable, while NTC10K/PT1000 automatic or manual temperature compensation ensures the displayed value always refers to the correct 25 °C baseline.
Two SPST relays, two active 4~20mA outputs and an RS485 Modbus RTU interface make the AEC1-T1 T2 a complete measuring and control node for water treatment, desalination, food & beverage, and industrial process water applications.
| Parameter | Specification |
|---|---|
| Product Model | AEC1-T1 T2 |
| Measurement Method | 2-electrode method |
| Conductivity Range | 0~20 mS/cm, min. resolution 0.001 µS/cm |
| Resistivity Range | 0~18 MΩ·cm, min. resolution 0.001 MΩ·cm |
| TDS Range | 0~10000 ppm, min. resolution 0.001 ppm |
| Salinity Range | 0~15 ppt, min. resolution 0.001 ppt |
| Temperature Range | -10~150 °C, resolution 0.1 °C |
| Accuracy | Conductivity ±1% FS; Temp. ±0.5 °C |
| Temp Compensation | NTC10K / PT1000 automatic or manual |
| Relay Control | Two SPST relays, 3A 250V AC |
| Analog Output | Two active 4~20mA or 0~20mA, max. load 1000 Ω |
| Communication | T1 without; T2 with RS485, Modbus RTU |
| Display Screen | 3.2 inch graphic LCD |
| Power Supply | 100~240VAC or 18~36VDC, 3W Max |
| Protection Grade | IP66 |
| Mounting / Dimension | Panel mounting, 100×100×120 mm, ~500 g |
It measures conductivity, resistivity, TDS, salinity and temperature. Use the arrow key to switch between conductivity (COND), resistivity (RES), TDS and salinity (SAL) in measurement mode.
The range is 0~20 mS/cm with a minimum resolution of 0.001 µS/cm.
Conductivity accuracy is ±1% FS and temperature accuracy is ±0.5 °C.
The controller supports NTC10K or PT1000 sensors in automatic or manual mode and displays the conductivity value referenced to 25 °C.
Yes, the enclosure is rated IP66 and is designed for panel mounting.
Contact Daruifuno today for samples, pricing and probe selection advice for the AEC1-T1 T2 conductivity analyzer.
Contact Person: Yuki Fu
Tel: +8615716217387