Send Message
Home ProductsTurbidity Analyzer

RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring

RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring
RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring
RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring

Large Image :  RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE, ISO
Model Number: DUC2-TU-S-D
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 5-25 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring

Description
Product Name: Turbidity Controller Display Range: 0.001NTU~4000NTU
Relay Control: 2 Settable SPST Relays Analog Current Output: 2 Settable 0/4~20mA
Communication Method: Two-wire RS485 Interface OTA: Default WIFI
Configuration Information: Power Off Protection Time/Data Record: Record 14000 Historical Data
Protection Level: IP66 Shell Material: Enhanced ABS
High Light:

Waste Water Monitoring Turbidity Controller

,

Signal Data Collection Turbidity Controller

,

RS485 Turbidity Controller

RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring

 

 

Principle: The turbidity online analyzer injects a laser beam from the air into the water in a direction perpendicular to the water surface. The laser light is scattered by the suspended particles in the water, and the sensor in the water detects the scattered light intensity in a direction 90 degrees from the incident light, and converts the scattered light intensity into a turbidity value according to the calibration table.

 

DRFN is a professional production and sales of turbidity meter, turbidity meter, online turbidity meter, online turbidity meter, mlss sludge concentration meter, ss suspended solids concentration meter, online dissolved oxygen meter, fluorescence dissolved oxygen meter, sludge interface Manufacturer of online monitoring and analysis instruments for water quality such as instrument, residual chlorine analyzer, ultrasonic liquid level meter, PH meter and so on.

 

Specification:

Model DUC2-TU-S-D
Software Version DRFN TU Analysis software V1.0
Sensor Input Compatible with all DRFN's TU Digital Sensors
Display Range 0.001NTU~4000NTU
Resolution 0.001 NTU
Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output 2 settable 0/4~20mA current outputs with a maximum load 1000Ω
Communication Method Two-wire RS485 interface; MODBUS RTU; support JSON text data format
OTA

Default WIFI

Display Screen

128*64 black-and-white graphic lattice LCD

adjustable backlight mode

adjustable display rate

Configuration Information Power off protection, parameters are retained indefinitely
Time/Data Record

Year/month/day/hour/min/second, record 14000 historical data

record interval can be set between 1~999 minutes

Maintenance Records Last 100 times
Protection Level IP66
Operating Environment 0~60℃,RH<95% ( no condensation)
Storage Environment -20~70℃,RH<55% ( no condensation, precision instruments)
Shell Material Enhanced ABS
Dimension 144*144*120 mm
Mounting Method Wall mounting, pipe clamping, panel installation (hole size 138*138 mm)
Electrical Interface The back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply

18~36VDC

Power Consumption About 12W
Weight About 800g

Please click the user manual of RS485 turbidity controller here:

DUC2 -HTU Turbidity controller user manual.pdf

 

Brief introduction:

● Compatible with all DRFN digital infrared turbidity sensors;
● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
● The working status of the sensor can be queried, including reading the serial number;
● Support a variety of installation methods;
● Time and historical data recording function;
● 3.2-inch large LCD screen;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

● OTA download technology as a smart configuration option for the instrument;

 

RS485 Signal Data Collection Turbidity Controller For Waste Water Monitoring 0

Aplication:
◇ Tap water
◇ Water station
◇ Surface water
◇ Sewage

◇ Industrial water

◇ Swimming pool


FAQ

Q1. What are the advantages of a digital turbidity meter?

A: The digital universal controller is matched with the corresponding digital sensor to realize the measurement. Compared with the traditional instrument and sensor combination, the biggest advantage is that the data transmitted from the sensor to the controller is more stable and accurate, the application is flexible, and the use is more convenient.

 

Q2. How does this turbidity controller collect data?

A: This digital turbidity meter is a single-parameter universal controller. Each controller will be pre-installed with a set of embedded software to correspond to different sensors. These connected sensors upload the detected data with a special encrypted communication method to ensure that the controller can collect high-precision data more stably. The controller will display the collected data on the display screen in real time, which is convenient for users to read.

 

Q3.Can customer's logo be added to the controller system and cover?
Of course, we support OEM services for customers. 

 

Q4.How long is the warranty period?
The company guarantees the instrument for one year (12 months) from the date of shippment, and the consumables and wearing parts in the equipment are not covered by the warranty.

 

Q5. Does the turbidity controller with a OTA function:

Yes. Our DUC2-TU-S Turbidity controller with OTA

 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)