Product Details:
|
Product Name: | Turbidity Analyzer | Product Model: | DUC2-HTU-S-A |
---|---|---|---|
OTA: | Default WIFI | Software Version: | DRFN TU Analysis Software V1.0 |
Turbidity Display Range: | 0.001NTU~4000NTU | Turbidity Resolution: | 0.001 NTU |
Operating Environment: | 0~60℃ | Protection Grade: | IP66 |
Size: | 144*144*120mm | Power Supply: | 100~240V AC |
High Light: | IP66 water turbidity meter,WIFI water turbidity meter,0.001 NTU Turbidity Analyser |
Digital Infrared Turbidity Analyzer For Water And Wastewater Tu Measurement
Brief Introduction
The turbidity analyzer has 2 settable multi-function SPST relays and 2 high-precision 0/4~20mA current outputs. The operating temperature of the controller is 0~60℃.
The protective grade of the turbidity controller is IP66, which can effectively isolate the pollution of the external environment and the invasion of the corrosive gas. Rich output configurations are available to meet the different detection needs of many applications.
The universal digital turbidity analyzer is designed specifically for the DRFN digital series of turbidity sensors, compatible with all DRFN infrared digital turbidity sensors.
The connected sensors upload the detected data in a special encrypted communication method to ensure that the DUC controller can collect high-precision data in a more stable manner.
Advantages Of The Turbidity Analyzer
There are clock and historical data recording functions to meet higher data management requirements. The DUC turbidity analyzer can record 14000 historical data, record interval can be set between 1~999 minutes. The meter has power-off protection, parameters are retained indefinitely.
The meter has a 3.2-inch display screen, using a 128*64 LCD screen, the backlight provides light and energy-saving mode to select. The language of it is Chinese or English.
Rich output to meet monitoring, control, and data remote transmission at the same time.
The DUC universal turbidity meter can accommodate a wide range of mounting options and can also be supplied with the necessary mounting accessories for installation.
Configured with OTA download technology (Over-the-Air Technology), as the intelligent configuration option of the instrument, OTA uses wireless technology connection of WIFI; GSM; CDMA, etc. to remotely upgrade software, diagnose faults and assist in various tasks such as instrument parameter configuration for customers, which reduces the workload of instrument field service and also minimizes the time of users waiting for service.
Applications Of The Turbidity Analyzer
Surface water, drinking water quality, municipal network water quality monitoring, industrial process water quality monitoring, wastewater treatment plant turbidity measurement, etc.
Technical Parameters
Product Name |
Turbidity analyzer |
Product Model |
DUC2-HTU-S-A |
Software Version |
DRFN TU Analysis software V1.0 |
OTA | Default WiFi |
Turbidity Display Range |
0.001NTU~4000NTU |
Turbidity Resolution |
0.001NTU |
Relay Control |
2 settable SPST relays max. load 3A/250VAC |
Analog Current Output |
2 settable 0/4~20mA active current loop output max. load 1000Ω |
Communication Method |
MODBUS RTU; support JSON text data format |
Display Screen |
128*64 LCD, adjustable backlight mode |
Time History/Data Record |
Year/month/day/hour/min/second, record 14000 historical data |
Protection Level |
IP66 |
Operating Environment |
0~60℃, relative humidity less than 95% |
Storage Environment |
-20~70℃, relative humidity less than 55% |
Shell Material |
Enhanced ABS |
Size |
144*144*120mm (hole size 138*138 mm) |
Mounting Method |
Wall mounting, pipe clamping, panel mounting |
Power Supply |
100~240V AC |
Weight |
800g |
Power Consumption |
12W |
Cleaning System | max. 24W(laser circulation sensor optional item) |
Product Name | Laser turbidity sensor | |||||
Product Model | OLTU600 | OLTU601 | OLTU602 | OLTU603 | ||
Measuring Range | 0.01~100NTU | |||||
Light Source | 660nm laser light source | |||||
Display Accuracy | 0.001~40NTU is ±2% of reading or ±0.015NTU take the larger one; 40~100NTU is ±5% of reading | |||||
Operating Environment | 0~45℃ | |||||
Flow Rate | 100ml/min≤x≤500ml/min | |||||
Calibration | Standard solution calibration, water sample calibration, zero point calibration | |||||
Cable Length | 3m standard cable, extension is not recommended | |||||
Sample interface | Injection port: 1/4NPT, discharge port: 1/2NPT | |||||
Main Material | Body: ABS+Nylon | |||||
Dimensions | Length 140*width 117*height 214mm | |||||
Net Instrument Weight | 2Kg | |||||
Waterproof Level | IP66 | |||||
Storage Temperature | -15~65℃ |