Product Details:
|
Product Name: | Residual Chlorine Controller | Product Model: | ADS2-U3D-CS4 |
---|---|---|---|
Software Version: | DRFN Chlorine Analysis Software V1.0 | Display Range: | 0.00-200.00mg/L |
Protection Grade: | IP66 | Size: | 144*144*120mm |
Power Supply: | 18~36V DC | Weight: | 800g |
Power Consumption: | 10W | Mounting Method: | Wall Mount, Pipe Clamping, Panel |
Highlight: | wastewater Chlorine Analyzer,RS485 Residual Chlorine Controller,4 20mA Residual Chlorine Controller |
Universal Disinfection Residual Chlorine Controller Used Under 4 ~ 9pH
Introduction
In the water treatment process, chlorination disinfection is an important part of water quality control in water plants. The DRFN's ADS2-U3D-CS4 residual chlorine controller is a single-parameter instrument, it is connected to the residual chlorine sensor to realize the measurement of the chlorine.
Advantages Of The Residual Chlorine Controller
1. A 128*64 black and white graphic dot matrix screen, the display backlight provides constant light and energy-saving mode selection.
2. All the configuration entered by the user is kept indefinitely, even if there is no power, the data will not be lost.
2. Record the user's maintenance details of the equipment, the calibration effect of the diagnostic sensor, and will give corresponding prompts for inaccurate calibration instruments.
3. Two-wire RS485 interface, the communication protocol is MODBUS RTU, support JSON text data format.
4. Menu password can be set to facilitate hierarchical management;
5. The residual chlorine meter has clock and historical data recording functions to meet higher data management requirements.
6. Support a variety of installation methods and can be applied to more different installation environments. The enclosure protection level is IP66.
Parameters Of The Residual Chlorine Controller
Product Name | Residual Chlorine Controller |
Product Model |
ADS2-U3D-CS4 |
Software Version |
DRFN Chlorine Analysis software V1.0 |
Display Range |
0.00-200.00mg/L |
Resolution |
0.001 mg/L |
Accuracy |
Better than 0.15% of the measuring range |
Stability |
0.05% of the measuring range every 24 hours, no accumulation |
Repeatability |
Better than 0.1% of the measuring range |
Relay Control |
2 settable SPST relays, the max. load 3A/250VAC |
Sensor Self-diagnosis |
screen image and buzzer prompt |
Analog Current Output |
2 settable 0/4~20mA active current loop output max. load 1000Ω |
Communication Method |
MODBUS RTU; support JSON text data format |
Display Screen |
128*64 LCD |
Time History/Data Record |
Year/month/day/hour/min/second, record 14000 historical data |
Protection Grade |
IP66 |
Operating Environment |
0~60℃, relative humidity less than 95% |
Storage Environment |
-20~70℃, relative humidity less than 55% |
Shell Material |
Enhanced ABS |
Dimensions |
144*144*120mm (hole size 138*138 mm) |
Mounting Method |
Wall mounting, pipe clamping, panel installation |
Power Supply |
18~36V DC |
Weight |
800g |
The Matching Chlorine Sensors Recommendation
Pressure range: 0~3.0 bar
Response time: T90 about 2 min
Flow rate: about 30 l/h, low flow-dependence
Connection: for mA-version 2-pole terminal, M12 male
Type: |
Measuring range: ppm |
Resolution: ppm |
Output signal: | Power supply: | Item number: |
CS4MA2 | 0.01~2.00 | 0.01 |
4~20 mA |
12~30 V DC RL: 50~900Ω |
3426303 |
CS4MA5 |
0.01~5.00 |
0.01 | 3426304 | ||
CS4MA10 | 0.01~10.00 | 0.01 | 3426305 | ||
CS4MA20 | 0.01~20.00 | 0.01 | 3426306 | ||
CS4MA200 | 0.5~200.0 | 0.1 | 3426307 | ||
CS4MA2-M12 | 0.01~2.00 | 0.01 |
4~20 mA |
12~30 V DC RL: 50~900Ω |
3426313 |
CS4MA5-M12 | 0.01~5.00 | 0.01 | 3426314 | ||
CS4MA10-M12 | 0.01~10.00 | 0.01 | 3426315 | ||
CS4MA20-M12 | 0.01~20.00 | 0.01 | 3426316 | ||
CS4MA200-M12 | 0.5~200.0 | 0.1 | 3426307 |
Contact Person: Ms. Yuki Fu
Tel: +8615716217387