Send Message
Home ProductsCOD Analyzer

Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment

Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment
Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment
Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment

Large Image :  Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE
Model Number: DUC2-COD-S-A
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable

Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment

Description
Product Name: COD Controller Product Model: DUC2-COD-S-A
Software Version: DRFN COD Analysis Software V1.0 Resolution: 0.01 Mg/L
Communication Protocol: MODBUS RTU Communication Interface: RS485
Housing Material: ABS Size: 144*144*120mm
Power Supply: 100~240V AC Power Consumption: 12W
Weight: 800g
High Light:

ABS chemical oxygen demand meter

,

12W cod measurement instrument

,

RS485 chemical oxygen demand meter

 

Online COD Controller For Wastewater And Sewage Treatment

 

Brief Introduction 

 

  • COD (chemical oxygen demand) is often used as an index to measure the amount of organic matter in the water. The greater the COD, the more serious the pollution of the water body by organic matter. Generally, the COD value of clean drinking water is a few to ten mg/L;

  • The DUC2-COD-S-A is a universal controller specially designed for the DRFN digital series of COD sensors and is compatible with all digital COD sensors of DRFN;

  • The COD controller can query the working status of the sensor, including the serial number of the sensor;

  • 2 high-precision 0/4~20mA current outputs with a maximum load of 1000 ohms;

  • 2 settable SPST multifunctional relays with a maximum load of 3A/250V AC;
  • The enclosure protection grade is IP66, can effectively isolate the pollution and corrosive gas from the external environment;

  • The COD instrument has a two-wire RS485 interface, the communication protocol is MODBUS RTU, and supports JSON text data format;

  • The shell material of the cod analyzer is enhanced ABS, its overall size is 144*144*120mm.

 

Advantages Of The COD Controller

 

  • This controller is equipped with RS485 Modbus RTU, RS485 allows multiple devices to be connected to the same bus and perform data transmission and control through serial communication protocols, making the integration between devices simpler and more flexible. RS485 uses differential signal transmission, which can resist electromagnetic interference in industrial environments and ensure stable data transmission. RS485 can support relatively long communication distances, allowing devices to be distributed in distant locations while maintaining reliable communication.

  • Menu password can be set to facilitate user's data confidentiality;

  • Clock and historical data recording function, which can record 14,000 historical data, and the recording interval can be set between 1 and 999 minutes.

  • 3.2-inch display screen and a 128*64 black and white graphic dot matrix LCD liquid crystal display, with reasonable interface settings and simple operation;

  • The COD controller has a power-off protection configuration, and the parameters can be kept indefinitely;
  • The display backlight of this instrument provides a choice of always-on and energy-saving modes, which users can set according to their needs;

  • The connected sensors upload the detected data in a special encrypted communication method to ensure that the DUC controller can collect high-precision data in a more stable manner.

  • DUC series COD analyzer can meet a variety of installation methods, such as wall-mounted installation, pipe clamp installation, panel installation, and provide accessories required for installation.

Online Chemical Oxygen Demand Meter For Wastewater Sewage Treatment 0

 

 

Applications Of The COD Controller

 

River water, surface water, process water, sewage treatment plant, industrial wastewater, drinking water.

 

 

Technical Parameters

 

Product Name

COD Controller

Product Model

DUC2-COD-S-A

Software Version

DRFN COD analysis software V1.0

Display Range

0-1000 mg/L

Resolution

0.01 mg/L

Relay Control

2 settable SPST relays max. load 3A/250VAC

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

Two-wire RS485 interface; MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data

Protection Level

IP66

Operating Environment

0~60℃, relative humidity less than 95% (no condensation)

Storage Environment

-20~70℃, relative humidity less than 55% (no condensation)

Shell Material

Enhanced ABS

Size

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel mounting

Power Supply

100-240V AC

Weight

800g

Power Consumption

12W

 

 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Ms. Yuki Fu

Tel: +8615716217387