Product Details:
|
Item Name: | PH And ORP Controller | Detection Channel: | Two Analog Channel Input |
---|---|---|---|
Historical Data: | Can Record 10,000 Historical Data | Calibration Log: | Records The Last 100 Times |
Relay Output: | 2 Configurable SPST Relays | Current Output: | 2 Channel 0/4~20mA |
Communication Interface: | RS485 Interface MODBUS RTU | Protection Grade: | IP66 |
Operating Environment: | 0~60℃ | Storage Environment: | 20~70℃ |
Instrument Dimensions: | 144*144*120mm | Installation Method: | Wall Mounting, Pipe Clamp, Panel |
Shell Material: | Reinforced ABS | Power Requirements: | AC: 100~240V, 50~60Hz; DC: +18~36V |
Dule Channels Analog PH And ORP Controller With RS485 And Two Relays Water Treatment
Daruifuno brand APX2-PD dual-channel controller connected to two analog signal channels at the same time: one can be selected for pH electrode and one for ORP (oxidation-reduction potential) electrode, both can be connected to analog pH electrode, and both can be connected to analog ORP electrode.
The analog signal (usually mV or 4~20mA) is amplified, filtered, linearly converted, and displayed, output or triggered relay action after internal processing. It supports measurement, calibration and control of pH and ORP respectively.
Product Parameters
Model | APX2-PD-A | APX2-PD-D | |
Measuring Objects | 2 measurement channel inputs, pH or ORP can be selected arbitrarily | ||
Principle | PH | Glass pH electrode (hydrogen ion concentration index) | |
ORP | Platinum or gold electrodes (redox potential) | ||
Display Range | PH: 0~14pH ORP: ± 2000mV Temp: -10~150℃ | ||
Resolution | PH: 0.01pH ORP: 1mV TEMP: 0.1℃ | ||
Accuracy | 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one | ||
Stability | 0.05% of measuring range every 24 hours without accumulation | ||
Repeatability | Better than 0.1% of measuring range | ||
Temp. Compensation | Automatic or manual (NTC10K/PT1000) | ||
Relay Output | Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp. or clean control | ||
Digital Communication | A two-wire RS485 interface, Modbus RTU and JSON | ||
Current Output | Two 0/4~20mA current Max. load 1000Ω | ||
Time Display | Year/month/date hour/minute/second | ||
Historical Data | Record 10000 historical data and the last 100 calibration maintenance data | ||
Valuation Object* | Built-in matrix (equivalent to residual chlorine) 0~2.5mg/L | ||
Support user-defined (20x20 matrix) | |||
Linear correspondence (water sample stability) | |||
Display | 128*64 3.2-inch graphic dot matrix LCD | ||
Calibration Method | PH: 3 points ORP: 2 points, calibration points can be set freely | ||
Material | Enhanced ABS Protection Grade: IP66 | ||
Power Supply | AC: 100~240V 50/60Hz | DC: 18~36V | |
Dimension | 144*144*120mm (Hole size 138*138mm) | ||
Work Temperature | 0~60℃, RH<95%, non-condensing | ||
Storage Temperature | -20~70℃, RH<55%, non-condensing | ||
Installation | Wall mounting, pipe clamp, panel |
Advantages and features
Daruifuno PH ORP controller APX2-PD history record and electronic clock function1. History recording function
1.Store measurement data, alarm events, etc.
Recording interval can be set (such as every 10 minutes)
2. Electronic clock function
Real-time clock module to ensure accurate event recording time
Used for timing control (such as cleaning time, calibration)
Daruifuno PH ORP controller APX2-PD two-way relay control dosing principle
Set the pH upper/lower limit. When the set value is exceeded, the relay will be activated.
Example: pH > 9, start the acid dosing pump;
pH < 6, start the alkali dosing pump;
You can set the hysteresis interval to avoid frequent switching.
Daruifuno PH ORP controller APX2-PD automatic cleaning control principle
The cleaning relay can be set to start at a fixed time (such as every 24 hours); the flushing time setting
starts the solenoid valve or water pump to clean the electrode
avoids measurement errors caused by adhesion on the electrode surface.
Daruifuno PH ORP controller APX2-PD pH and ORP calibration method
1. pH calibration:
Use standard buffer: pH 4.01, 7.00, 10.01, PH ORP controller produced by our company Daruifuno, the calibration point can be set freely.
Single point calibration: Use pH 7.00 liquid to calibrate the zero point.
Two-point calibration: pH 7.00 and 4.00 or 10.00, calibrate the zero point and slope.
The controller guides the operation, automatically determines stability and stores.
2. ORP calibration:
Use standard buffer, such as +220mV or +470mV.
The calibration process is simple, usually a single point is sufficient.
Daruifuno PH ORP controller APX2-PD controller installation methodInstallation method:
Aplication:
◇ Surface water
◇ Source water
◇ Aquaculture waters
◇ Landscape water
◇ Import of the waterworks
◇ Water treatment monitoring
◇ Drinking water,
◇ Groundwater, swimming pool
◇Industrial process monitoring and dosing control management
◇Chemical, petroleum, paper, food and medicine, electroplating, PCB manufacturing, etc.
◇ Municipal/industrial water treatment
◇ Circulating cooling water monitoring
◇ Electroplating/chemical liquid control
◇ Food and beverage production line
◇ Acid-base neutralization reaction tank control
Contact Person: Yuki Fu
Tel: +8615716217387