logo
  • English
Home ProductspH ORP Controller

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment
Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment
Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

Large Image :  Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: ISO, CE
Model Number: APX2-PD
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable
Delivery Time: 1-30days

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

Description
Item Name: PH And ORP Controller Detection Channel: Two Analog Channel Input
Historical Data: Can Record 10,000 Historical Data Calibration Log: Records The Last 100 Times
Relay Output: 2 Configurable SPST Relays Current Output: 2 Channel 0/4~20mA
Communication Interface: RS485 Interface MODBUS RTU Protection Grade: IP66
Operating Environment: 0~60℃ Storage Environment: 20~70℃
Instrument Dimensions: 144*144*120mm Installation Method: Wall Mounting, Pipe Clamp, Panel
Shell Material: Reinforced ABS Power Requirements: AC: 100~240V, 50~60Hz; DC: +18~36V

 

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

 

Daruifuno brand APX2-PD dual-channel controller usually supports simultaneous connection of one analog pH electrode and one analog ORP (oxidation-reduction potential) electrode, or two analog pH sensors and two analog ORP sensors. The pH value and oxidation-reduction potential (mV value) of the solution are collected respectively. The internal analog circuit converts the electrode signal into a standard voltage signal, amplifies and filters it, and then the microprocessor of the controller performs numerical processing and judgment, thereby outputting a relay control signal or an analog current (such as 4-20mA) signal.
pH channel: measures pH (0-14) and controls acid/base dosing.
ORP channel: measures oxidation-reduction potential (±2000mV) for disinfection (such as chlorination) or dechlorination.
The electrode is connected to the controller terminal; the controller relay output is connected to the dosing pump, alarm or cleaning device; the control logic, calibration, cleaning cycle, etc. can be set through the menu; regular calibration and data viewing are supported.

 

Product Parameters

 

Model APX2-PD-A APX2-PD-D
Measuring Objects 2 measurement channel inputs, pH or ORP can be selected arbitrarily
Principle PH Glass pH electrode (hydrogen ion concentration index)
ORP Platinum or gold electrodes (redox potential)
Display Range PH: 0~14pH ORP: ± 2000mV Temp: -10~150℃
Resolution PH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability 0.05% of measuring range every 24 hours without accumulation
Repeatability Better than 0.1% of measuring range
Temp. Compensation Automatic or manual (NTC10K/PT1000)
Relay Output Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp. or clean control
Digital Communication A two-wire RS485 interface, Modbus RTU and JSON
Current Output Two 0/4~20mA current Max. load 1000Ω
Time Display Year/month/date hour/minute/second
Historical Data Record 10000 historical data and the last 100 calibration maintenance data
Valuation Object* Built-in matrix (equivalent to residual chlorine) 0~2.5mg/L
Support user-defined (20x20 matrix)
Linear correspondence (water sample stability)
Display 128*64 3.2-inch graphic dot matrix LCD
Calibration Method PH: 3 points ORP: 2 points, calibration points can be set freely
Material Enhanced ABS Protection Grade: IP66
Power Supply AC: 100~240V 50/60Hz DC: 18~36V
Dimension 144*144*120mm (Hole size 138*138mm)
Work Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Wall mounting, pipe clamp, panel

 

​Advantages and features

  • Dual-channel input: supports simultaneous connection of two electrodes (pH+pH, ORP+ORP, or pH+ORP) monitors pH and ORP at the same time, improves efficiency and saves installation space
  • Dual-channel relay output: can set high/low alarm, dosing control and other functions
  • Analog signal output (4-20mA): provides 4-20mA output, which is convenient for docking with PLC and DCS systems
  • High-definition LCD display Real-time display of pH/ORP, electrode status, temperature, relay status, etc.
  • History recording function: stores measurement data and alarm records for easy traceability
  • Electronic clock: provides timestamp, cooperates with data recording Built-in history record and electronic clock, you can query the time of key events
  • Automatic cleaning control: provides cleaning relay output, supports timing or conditional trigger cleaning function to extend electrode life
  • Multiple calibration methods: supports 1-point, 2-point or multi-point calibration to improve accuracy
  • Two Channels are isolated from each other
  • Each channel can be connected to an independent temp. system.
  • When pH, ORP and temp. are tested at the same time, the algorithm inside the meter can simultaneously evaluate the disinfection ability and display pH, ORP, temp. and chlorine values.
  • Meet pH/ORP monitoring, dosing control, and data signal remote transmission at the same time.
  • Menu-based operation Multi-language support, user-friendly interface, simple operation

Daruifuno PH ORP controller APX2-PD history record and electronic clock function1. History recording function
1.Store measurement data, alarm events, etc.
Recording interval can be set (such as every 10 minutes)
2. Electronic clock function
Real-time clock module to ensure accurate event recording time

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 0

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 1

 

Daruifuno PH ORP controller APX2-PD two-way relay control dosing principle
Set the pH upper/lower limit. When the set value is exceeded, the relay will be activated.
Example: pH > 9, start the acid dosing pump;
pH < 6, start the alkali dosing pump;
You can set the hysteresis interval to avoid frequent switching.

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 2

 

Daruifuno PH ORP controller APX2-PD automatic cleaning control principle

The cleaning relay can be set to start at a fixed time (such as every 24 hours); the flushing time setting
starts the solenoid valve or water pump to clean the electrode
avoids measurement errors caused by adhesion on the electrode surface.

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 3

 

Daruifuno PH ORP controller APX2-PD pH and ORP calibration method
1. pH calibration:
Use standard buffer: pH 4.01, 7.00, 10.01, PH ORP controller produced by our company Daruifuno, the calibration point can be set freely.
Single point calibration: Use pH 7.00 liquid to calibrate the zero point.
Two-point calibration: pH 7.00 and 4.00 or 10.00, calibrate the zero point and slope.
The controller guides the operation, automatically determines stability and stores.
2. ORP calibration:
Use standard buffer, such as +220mV or +470mV.
The calibration process is simple, usually a single point is sufficient.

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 4

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 5

 

Daruifuno PH ORP controller APX2-PD controller installation methodInstallation method:
Panel installation (opening installation, IP66 protection panel)
Wall installation (adaptive protection shell)
Pipeline installation
Installation environment:
Avoid direct sunlight, high temperature and high humidity;
Cables are routed separately to avoid sharing the same wiring trough with power lines;

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 6

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment 7

 

Aplication:
◇ Surface water
◇ Source water
◇ Aquaculture waters
◇ Landscape water
◇ Import of the waterworks

◇ Water treatment monitoring

◇ Drinking water,

◇ Groundwater, swimming pool

◇Industrial process monitoring and dosing control management

◇Chemical, petroleum, paper, food and medicine, electroplating, PCB manufacturing, etc.
◇ Municipal/industrial water treatment

◇ Circulating cooling water monitoring

◇ Electroplating/chemical liquid control

◇ Food and beverage production line
◇ Acid-base neutralization reaction tank control

 