Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE, ISO
Model Number: OZ1.2
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: carton
Delivery Time: 1-45 work days
Payment Terms: T/T

Two-Wire 4-20mA Two-Electrode Ozone Sensor

Description
Product Name: Ozone Sensor Product Model: OZ1.2
Measuring Range:: 0~0.5/2/5/10/20ppm Pressure Range: 0 ~ 1bar (Flow Cell)
Temperature Range: 0 ~ 45 ℃ Response Time: T90: Approx. 3 Min. (brine Approx. 5 Min.)
Flow Rate: 15-30 L/h (33 – 66 Cm/s)
Highlight:

Drinking Water Ozone Sensor

,

Direct Drinking Water Ozone Sensor

,

Service Process Water Ozone Sensor

Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water

 

Two-electrode system ozone sensor OZ1.2, used in drinking water, direct drinking water, service and process water, measuring water without surfactant, optional range 0~0.5/2/5/10/20ppm

 

The functional characteristics of the ampere film ozone sensor include high sensitivity and fast response, which can accurately measure the ozone concentration in water. Its advantages are strong anti-interference ability, suitable for various water quality environments, and long service life. It is suitable for drinking water and industrial water treatment to ensure water quality safety.

 

Two-Wire 4-20mA Two-Electrode Ozone Sensor 0

Specifications

 Two-Wire 4-20mA Two-Electrode Ozone Sensor 1

 

 

OZ1.2

 Indicator   Ozone
 
 Application

Swimming pool water, drinking water, service water, process water
The water must not contain any surfactants (tensides)!

 Measuring system   Membrane covered, amperometric 2-electrode system 

 

 

 

 

Electronic

Analog version: - voltage output

- not galvanically isolated electronics

- analog internal data processing

- output signal: analog (analog-out/analog)

Digital version:    - electronic is completely galvanically isolated

- digital internal data processing

- output signal: analog (analog-out/digital)

or

digital (digital-out/digital)

mA-version:        - current output analog

- not galvanically isolated electronics

- output signal: analog (analog-out/analog)

 

Information about the

measuring range

The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

Note: With a slope > 100% the measuring range is reduced accordingly.

(Ex.: 150% slope → 67% of the specified measuring range)

Slope drift

At repeatability conditions

(25 °C, pH 7,2 in drinking water)

  Approx. <- 1% per month

 

Working temperature

Measuring water temperature: 0 … +45 °C

(no ice crystals in measuring water)

  Ambient temperature: 0 … +55 °C

Temperature

compensation

Automatically, by an integrated temperature sensor
Sudden temperature changes must be avoided

 

 

Max. allowed working pressure

Operation without retaining ring:

- 0.5 bar

- no pressure impulses and/or vibrations

Operation with retaining ring in Flow cell:

- 1.0 bar,

- no pressure impulses and/or vibrations (see option 1)

 

 

Two-Wire 4-20mA Two-Electrode Ozone Sensor 2

 

 

OZ1.2

Flow rate

(Incoming flow velocity)

  Approx. 15-30 l/h (33 – 66 cm/s) in flow FLC, small flow rate dependence is given
  pH-range   pH 1 – pH 11
  Run-in time   First start-up approx. 1 h
  Response time   T90 : approx. 15 sec.
  Zero point adjustment   Not necessary
  Calibration   At the device, by analytical determination
  Interferences

Cl2: factor 0.03
ClO2: factor 0.7

  Absence of the disinfectant   Max. 24 h

 

Connection

mV version:

Modbus version:

4-20 mA version:

5-pole M12, plug-on flange

5-pole M12, plug-on flange

2-pole terminal

or

5-pole M12, plug-on flange

  max. length of sensor cable   (depending on internal signal   processing)  analog   < 30 m
 digital

> 30 m are permissible

Maximum cable length depends on application

  Protection type

5-pole M12 plug-on flange: IP68

2-pole terminal with mA-hood: IP65

  Material   Semipermeable membrane, PVC-U, ABS

 

 

Size

Diameter:

Length: mV version

Modbus version 4-20 mA version

approx. 25 mm

approx. 190 mm (analog signal processing)

approx.. 205 mm (digital signal processing)

approx. 205 mm

approx. 220 mm (2-pole-terminal)

approx. 190 mm (5-pole-M12)

  Transport  +5 … +50 °C (sensor, electrolyte, membrane cap)

 

 

Two-Wire 4-20mA Two-Electrode Ozone Sensor 3

 

 

OZ1.2

 

 

Storage

  Sensor: dry and without electrolyte no limit at +5 … +40 °C

Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1

year or until specified EXP-Date

Membrane cap: in original packing no limit at +5 … +40 °C

(used membrane caps can not be stored)

 

Maintenance

Regularly control of the measuring signal, min. once a week

The following specifications depend on the water quality:

Change of the membrane cap: once a year (depending on the water quality)

Change of the electrolyte: every 3 - 6 months

Two-Wire 4-20mA Two-Electrode Ozone Sensor 4  

 

  Option 1:

Retaining ring

 

 

 

 

  - When operating with pressures >0.5 bar in flow cell

  - Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

  - Different positions for groove selectable(on request)

 

Two-Wire 4-20mA Two-Electrode Ozone Sensor 5

Two-Wire 4-20mA Two-Electrode Ozone Sensor 6

 

Technical Data

1. OZ1.2 (analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
isolation.

        Two-Wire 4-20mA Two-Electrode Ozone Sensor 7

Measuring range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mV/ppm

Voltage

supply

 Connection
OZ1.2H-M12  0.005…2.000   0.001

 

 

0…-2000 mV

1 kΩ

  - 1000

 

 

±5 - ±15 VDC

10 mA

5-pole M12 plug-on flange

 

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: -U

PIN4: signal GND

PIN5: n. c.

 OZ1.2N-M12  0.05…20.00   0.01   - 100
OZ1.2HUp-M12  0.005…2.000   0.001

 

 

0…+2000 mV

1 kΩ

  +1000

 

 

10 - 30 VDC

10 mA

5-pole M12 plug-on flange

Function of wires:

 

PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

 OZ1.2NUp-M12 0.05…20.00   0.01   +100

(Subject to technical changes!)

 

2. OZ1.2 (analog output, digital signal processing)
Analog-out / digital
-The power supply is galvanically isolated inside of the sensor.
-The output signal is galvanically isolated too, that means potential-free.

         Two-Wire 4-20mA Two-Electrode Ozone Sensor 8

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Nominal

Slope

in mV/ppm

Power supply Connection
 OZ1.2H-An-M12  0.005…2.000  0.001

analog

0…-2 V

(max. -2.5 V)

1 kΩ

 - 1000

 

 

9-30 VDC

approx. 20-56 mA

5-pole M12 plug-on

flange

 

Function of wires:

PIN1: measuring signal

PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

 OZ1.2N-An-M12  0.05…20.00  0.01  - 100
 OZ1.2H-Ap-M12  0.005…2.000  0.001

analog

0…+2 V

(max. +2.5 V)

1 kΩ

 +1000
 OZ1.2N-Ap-M12  0.05…20.00  0.01  +100

(Subject to technical changes!)

 

3. OZ1.2 (digital output, digital signal processing)
-The power supply is galvanically isolated inside of the sensor.
-The output signal is galvanically isolated too, that means potential-free.

Two-Wire 4-20mA Two-Electrode Ozone Sensor 9

Measuring

range

in ppm

Resolution

in ppm

Output

Output resistance

Power supply Connection
 OZ1.2H-M0c  0.005…2.000  0.001

  Modbus RTU

 

There are no terminating resistors in the sensor.

  9-30 VDC

 

approx. 20-56 mA

5-pole M12 plug-on flange

Function of wires:

PIN1: reserved

PIN2: +U

PIN3: power GND

PIN4: RS485B

PIN5: RS485A

 OZ1.2N-M0c  0.05…20.00  0.01

(Subject to technical changes!)

 

4. OZ1.2 4-20 mA (analog output, analog internal signal processing)
A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
isolation.
4.1 Electrical connection: 2 pole terminal clamp

 Two-Wire 4-20mA Two-Electrode Ozone Sensor 10

Measuring

range

in ppm

Resolutio n

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

 Connection
 OZ1.2MA0.5  0.005…0.500  0.001

  4…20 mA

uncalibrated

  32.0

 

  12…30 VDC

RL 50Ω…RL 900Ω

 

   2-pole terminal

(2 x 1 mm²)

 

Recommended:

Round cable

4 mm

 2 x 0.34 mm²

 OZ1.2MA2  0.005…2.000  0.001   8.0
 OZ1.2MA5  0.05…5.00  0.01   3.2
 OZ1.2MA10  0.05…10.00  0.01   1.6
 OZ1.2MA20  0.05…20.00  0.01   0.8

(Subject to technical changes!)

 

4.2 Electrical connection: 5 pole M12 plug-on flange

Two-Wire 4-20mA Two-Electrode Ozone Sensor 11

Measuring

range

in ppm

Resolution

in ppm

Output

Output

resistance

Nominal

slope

in mA/ppm

Voltage

supply

 Connection
 OZ1.2MA0.5-M12  0.005…0.500  0.001

   4…20 mA

uncalibrated

 32.0

  12…30 VDC

RL 50Ω…RL 900Ω

  5-pole M12

plug- on flange

 

Function of wires:

PIN1: n. c.

PIN2: +U

PIN3: -U

PIN4: n c.

PIN5: n. c.

 OZ1.2MA2-M12  0.005…2.000  0.001  8.0
 OZ1.2MA5-M12  0.05…5.00  0.01  3.2
 OZ1.2MA10-M12  0.05…10.00  0.01  1.6
 OZ1.2MA20-M12  0.05…20.00  0.01  0.8

(Subject to technical changes!)

 

Spare Parts

 Type  Membrane cap  Electrolyte  Emery  O-ring
For all OZ1.2

M20.2
Art. no. 11011.1

EOZ1/W, 100 ml
Art. no. 11101

S1
Art. no. 11908

14 x 1.8 silicone
Art. no. 11805

(Subject to technical changes!)

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)