Product Details:
|
Product Name: | DO Meter | DO Concentration: | 0-50mg/L (or Ppm) |
---|---|---|---|
Saturation Display: | 0-400% | Temperature Range: | -10~500℃ /14~932 |
Atmospheric Pressure Display Range: | 30-120kpa | Relay Control: | 2 Settable SPST Relays |
Analog Current Output: | 2 Settable 0/4~20mA | Communication Metho: | RS485 Interface |
Time/Data Record: | 14000 | Protection Grade: | IP66 |
Highlight: | RS485 Interface Dissolved Oxygen Meter,RS485 Interface Dissolved Oxygen Analyzers,IP66 Dissolved Oxygen Meter |
Online RS485 Interface Dissolved Oxygen Meter For Water Quality Monitoring
Dissolved oxygen, Usually recorded as DO. Expressed in milligrams of oxygen per liter of water, mg/L.
The content of dissolved oxygen in water is closely related to the partial pressure of oxygen in the air and the temperature of water. The lower the water temperature, the higher the dissolved oxygen content in the water.
Dissolved oxygen value is a basis for studying the self-purification ability of water. The dissolved oxygen in the water is consumed, and it takes a short time to restore to the initial state, indicating that the water body has strong self-purification ability, or the water body is not seriously polluted. Otherwise, it means that the water body is seriously polluted, the self-purification ability is weak, or even loses the self-purification ability.
Specification:
Model | DUC2-DO-H-A | |
Software Version | DRFN DO Analysis software V1.0 | |
Sensor Input | Compatible with all DRFN's DO Digital Sensors | |
Display Range | DO Concentration | DO concentration 0-50mg/L (or ppm), unit can be switched |
Saturation | 0-400% | |
TEMP | -10~500℃ /14~932℉ | |
Atmospheric Pressure | 30-120kpa | |
Resolution | DO Concentration | 0.01 mg/L(or ppm) |
Saturation | 1% | |
TEMP | 0.1℃/ 0.1℉ | |
Salinity Compensation Range | Input range 0.0001-99999ppt | |
Relay Control | 2 settable SPST relays with a maximum load of 3A/250VAC | |
Analog Current Output | 2 settable 0/4~20mA current outputs, max load 1000Ω | |
Communication Method |
RS485 interface |
|
OTA | —— | |
Display Screen | 128*64 LCD, adjustable backlight mode, adjustable display rate | |
Configuration Information | Power off protection, parameters are retained indefinitely | |
Time/Data Record |
Record 14000 historical data |
|
Maintenance Records | Last 100 | |
Operating Temperature | 0~60℃,RH<95% ( no condensation) | |
Storage Temperature | -20~70℃, RH<55% ( no condensation, precision instruments) | |
Shell Material | Enhanced ABS | |
Protection Grade | IP66 | |
Dimension | 144*144*120 mm | |
Mounting Method | Wall mounting, pipe clamping, panel (hole size 138*138 mm) | |
Electrical Interface | The back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm | |
Power Supply | 100~240VAC | |
Power Consumption | About 7W | |
Weight | About 800g |
Please click the user manual of DO controller here:
Brief introduction:
● Compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography;
● Automatic compensation for air pressure display;
● The working status of the sensor can be queried, including reading the serial number;
● OTA download technology as a smart configuration option for the instrument;
● Time and historical data recording function;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;
● Support a variety of installation methods
Aplication:
◇ Sewage
◇ Surface water monitoring
◇ Aquaculture water bodies
◇ Urban sewage treatment
◇ Industrial wastewater treatment
◇ Aquarium
FAQ
1. Which sensors can be connected to your dissolved oxygen controller?
A: The dissolved oxygen meter can be compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography.
2. How does your DO controller collect sensor data?
A: The connected sensor uploads the detected data in a special encrypted communication method to ensure that the DUC controller can collect high-precision data more stably
3. What are the applications of dissolved oxygen analyzers?
A: Sewage/Surface water monitoring/Aquaculture water bodies/Urban sewage treatment/Industrial wastewater treatment /Aquariums
4.Can the dissolved oxygen controller realize the automatic cleaning control function?
The DO controller has a self-cleaning control function, and Our DO sensor has a cleaning interface.
The end customer can choose water or air, Realize automatic cleaning. But the end user need to buy a solenoid valve himself.
5. Does the dissolved oxygen controller have an ambient temperature alarm function?
Our DO controller has ambient temperature alarm function
6: How long will you give me the reply?
A: We can support you 24Hours online service via email, skype, what’sapp, facebook etc within 1 hour.
7: How long is your delivery time?
A: Generally it is 3 days if the goods are in stock. or it is 7 days if the goods are not in stock, it is according to quantity.
8: Do you provide samples ? is it free or extra ?
A: NO, we could not offer the sample for free charge
9: What is your terms of payment ?
A: Payment<8000USD, 100% in advance. Payment>=8000USD, 30% T/T in advance ,balance before shippment.
Contact Person: Yuki Fu
Tel: +8615716217387