Send Message
Home ProductspH ORP Sensor

Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water

Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water
Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water

Large Image :  Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE, ISO
Model Number: ASP600-NYD05
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 5-15 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water

Description
Product Name: PH Sensor Materials: PPS+Glass+ceramics +Titanium
PH: 0~14pH Working Pressure:: 0~4Bar
Working Temperature: 0.0~100.0℃ Reference Electrode: Ag/AgCl
Ground: Titanium Solution Temperature Compensation: NTC10K
Cleaning: Cleaning Interface(Optional) Application: Industrial Sewage
High Light:

Titanium Solution Ground PH Sensor

,

Submerged Installation PH Sensor

,

Titanium Solution Ground PH ORP Sensors

 

Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water

 

During measurement or when the electrode is not used for a short time, the electrode needs to be stored in a container filled with electrolyte (eg: 3mol/L KCl) or buffer pH4 or pH7. Confirm that the electrolyte level in the container is lower than the filling level in the electrode.

 

Specification:

 Modle
 
  ASP600-NYD05
PH Range
0~14pH 0.01pH
Shaft Material
PPS
Working TEMP
0~100℃
Reference System
double salt bridge
Reference Electrode
Ag/AgCl
Electrolyte
Crystal
Working Pressure
0~4Bar
Temperature Unit
NTC10K
Membrane
Ceramic hole
Glass Head

Blue low impedance

 

Dimension
Diameter: 35mm Length: 260 mm ( include the cleaning cover)
Thread Size
1 inch NTP(both ends)
Lead Wire
Standard 5m
Ground
Titanium solution
Cleaning
A protective cover with its own cleaning interface(Optional)
Application
Pure water

 

Please click the catalog of pH controller here:

Daruifuno Catalog.pdf

 

Brief introduction:

◆ pH composite electrode, metal alloy titanium solution grounding electrode, strong corrosion resistance environment, used for accurate detection in severely polluted environments.
◆ Built-in high-precision NTC10K temperature resistance
◆ The body adopts high-performance PPS plastic shell encapsulation
◆ The electrode is equipped with a protective cover with its own cleaning interface
◆ Blue low-impedance hemispherical glass head
◆ Point-shaped ceramic hole sand core reference, the reference electrode is Ag/AgCl, the reference is filled with saturated KCL+excess KCL crystal, and the service life is long.
◆ The reference system is a double salt bridge design

 

Submerged Installation Titanium Solution Ground PH Sensor For Sewage Water 0

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

 

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

 

FAQ

1. What is themeasurement principle of this pH electrode?
A:
The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.


3. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.

 

4. What is the wire length of the pH electrode?
A: The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

 

5. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)