Send Message
Home ProductspH ORP Sensor

1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water

1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water
1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water
1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water 1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water 1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water 1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water

Large Image :  1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE
Model Number: ASP300-TYD05
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Carton
Delivery Time: 5-15 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water

Description
Product Name: PH Sensor Item: ASP300-TYD05
PH: 0~14pH 0.01pH Shaft Material: ABS+Glass+Teflong
Working Temperature: 0.0~60.0℃ Reference System: Double Salt Bridge
Reference Electrode: Ag/AgCl Working Pressure:: 0~2Bar
Temperature Compensation: PT1000 Cleaning: Cleaning Interface (Optional)
High Light:

1 Inch NTP PH Electrode

,

Industrial Water PH ORP Sensors

,

ABS PH Electrode

 

1 Inch NTP PH Electrode With Self-Cleaning Connector For Industrial Water

 

Composite electrodes are more convenient to handle than two separate half-cell electrodes and are very common today.

 

In the composite electrode, the pH-sensitive glass electrode is located in the middle, and the periphery is surrounded by a reference electrode filled with a reference electrolyte. The pH electrode and reference electrode part of the composite electrode have the same function as the independent electrode, the only difference is that the independent electrode is integrated into one electrode, which is more convenient to use. The use of a separate electrode is only recommended when the service life of the pH electrode and the reference electrode is very different. A more convenient electrode is to add a temperature probe to the composite electrode, so that temperature compensation can be easily performed. This electrode is called a 3-in-1 electrode.

 

 

Specification:

 Modle
 

 ASP300-TYD05
PH Range
0~14pH 0.01pH
Shaft Material
ABS
Working TEMP
0~60℃
Reference System
double salt bridge
Reference Electrode
Ag/AgCl
Electrolyte
Solid Gel
Working Pressure
0~2Bar
Operating Temperature
0~60℃
Working Pressure
0~2Bar
Temperature Unit
Vacant/NTC10K /PT1000 (optional)
Membrane
Porous Teflon

 Glass Head

 

 Transparent low impedance

 

Dimension
Diameter: 35mm Length: 260 mm ( include the cleaning cover)
Thread Size
1 inch NTP(both ends)
Lead Wire
Standard 5m
Ground
--
Cleaning
A protective cover with its own cleaning interface(Optional)
Application
Industrial water

 

Please click the user manual of pH sensor here:

PH sensor User Manual.pdf

 

Brief introduction:

◆ pH composite electrode, the body adopts reinforced ABS plastic shell encapsulation, the structure is firm, there are installation threads at the beginning and the end, and the installation is convenient;


◆ The electrode is equipped with a protective cover with its own cleaning interface, and the user can quickly access the automatic cleaning system;


◆ The electrode is divided into 3 basic models according to the packaging method of the temperature unit;
◆ The indicator electrode adopts a low-impedance hemispherical glass head, which has high strength and is not easily broken;


◆ The reference adopts a large-area annular porous Teflon membrane, which has fast penetration speed, fast response, not easy to block, and easy to clean;


◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, filled with KCL solid gel.

 

◆ Power supply mode: AC power supply 100~240VAC and DC power supply 18~36VDC.

 

1 Inch NTP PH Electrode With Self Cleaning Connector For Industrial Water 0

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

 

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

 

FAQ

1. What is themeasurement principle of this pH electrode?
A: The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.


3. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.


4. What is the wire length of the pH electrode?
A:
The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

 

5. How often must the pH sensor be calibrated?
A: Depends on the type of sample: Dirty samples and non-aqueous samples require more frequent calibration. Depends on the required accuracy: For very accurate measurements, at least daily calibration is required. Depends on the quality of the electrode: Old electrodes require more frequent calibration.

 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)