Send Message
Home ProductspH ORP Sensor

Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring

Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring
Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring

Large Image :  Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE, ISO
Model Number: DPH790-YD01A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 5-25 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring

Description
Product Name: PH Sensor Electrical Isolation: With Electrical Isolation
Measuring Range: PH: 0~14pH Operating Temperature: 0.0~50.0℃
Work Pressure: 0~2Bar Temp. Compensation: Automatic, Built-in Temperature Unit
Calibration Method: Zero Position/slope/deviation Material: ABS
Cleaning: Ceaning Interface (Optional) Protection Grade: IP68
High Light:

Aquaculture Fisheries PH ORP Probe

,

Freshwater Farming PH ORP Electrode

,

Cooling Circulating Water PH Sensor

 

Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring

 

 
The digital pH sensor adopts the classic electrochemical principle, which is reliable in measurement and stable in performance. It is widely used in environmental protection water treatment, surface water, purified water, circulating water and other systems, as well as electroplating, electronics, printing and dyeing, chemical, food, pharmaceutical and other process fields. Excellent performance in sewage treatment, drinking water treatment, surface water monitoring, pollution source monitoring, industrial process and other applications.
 
In order to obtain the best measurement results, regular maintenance is required. Maintenance includes cleaning of electrodes and checking for damage. Check whether the electrode wiring is correct, check the communication setting parameters (address, baud rate, parity bit, stop bit), etc.

 
Specification:

Model DPH79
Electrical Isolation
Measuring Range PH: 0~14pH TEMP: 0~50℃
Resolution 0.01pH/0.1℃
Accuracy ±0.02pH
Temperature Compensation Automatic, built-in temperature unit
Calibration Method Zero position/slope/deviation
Work Pressure 0~2Bar
Operating Temperature 0.0~50.0℃
Shell Material ABS
Dimension Diameter: 35mm Total length: 260 mm ( include cleaning cover)
Installation Size

1"NPT at both ends of the installation thread;
insertion depth 100 (including cleaning plug 115)

Protection Grade IP68
Weight 150g

Please click the user manual of RS485 pH sensor here:
DPH7 digital pH User Manual.pdf
 
Features& Advantages

● All-in-one package, can be used with the online transmitters, DTU, and portable instruments
● RS485 interface, Modbus RTU, support access to standard industrial control system
● The protection grade is IP68, can work continuously and stably under water for a long time
● Internal storage of calibration data, support offline calibration, plug and play on site

 
 
Built-In TEMP Electrical Isolation Digital PH Probe For Industrial Process Monitoring 0
Aplication:

Water treatment monitoring
Drinking water,surface water,water quality analyze,ground water,ect.

Industrial process monitoring and dosing control
Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

 
FAQ
1. What is the measurement principle of this pH electrode?

A: The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.

2. How to judge the pH of the solution?
A: If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.

3. What is the wire length of the pH electrode?
A: The lead wire of this electrode is 1 m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.
 

4. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.