Send Message
Home ProductsDissolved Oxygen Analyzer

Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring

Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring
Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring

Large Image :  Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: ISO9001 CE
Model Number: OPD79
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: $536
Packaging Details: Carton and PE foam
Delivery Time: negotiatable
Payment Terms: Western Union, L/C, T/T
Supply Ability: 100 piece/ month

Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring

Description
Product Name: Dissolved Oxygen Analyzer Model: OPD79
Range: 0.00~20.00 Mg/L Principle: Fluorescence Method
Pressure: 3bar Accuracy: 0.1mg/L
Communication: RS485 MODBUS RTU Protection Grade: IP68(sensor)
Operating Temperature: 0.0~50.0℃ Material: Enhanced ABS
High Light:

Dissolved Oxygen Sensor ABS

,

Water Station Dissolved Oxygen Sensor

,

0.1mg/L Dissolved Oxygen Analyzers

China Manufacturer Do probe Dissolved Oxygen Sensor for Water station

 

Compared with traditional polarographic electrodes, the fluorescence dissolved oxygen sensor developed and produced by Delfino is more suitable for real-time dissolved oxygen monitoring. Its shell is ABS sturdy and durable, the measurement results are accurate, and the maintenance is very easy. At the same time, it is also a digital electrode with built-in RS485 communication and supports Modbus protocol.

 

 
Specification of Dissolved Oxygen sensor
 

Model

OPD79
Measuring Range

Oxygen content: 0.00~20.00 mg/L
saturation: 0~200%

Resolution 0.01mg/L 1%
Accuracy 0.1 mg/L 1%
Response Time T90 less than 60s
Temperature Compensation Automatic, built-in temperature unit
Calibration Method Zero position/slope/deviation
Work Pressure 0~3Bar
Operating Temperature 0.0~50.0℃
Material ABS
Dimensions Diameter: 35mm Total length: 260mm
Installation Size

1"NPT at both ends of the installation thread;
insertion depth 100 (including cleaning plug 115)

Protection Grade IP68
Weight 170g

 
 
Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring 0

 
Features of the dissolved oxygen sensor


1. No need to calibrate, meet the requirements of on-site work
2. There is no need to consume oxygen, and it can be accurately measured even when the oxygen concentration is low.
3. With RS458 interface, it supports access to standard industrial control systems.
4. The protection grade is IP68, which can work continuously under water for a long time.
5. Internal storage of calibration data, plug and play on site.
6. No need for polarization, no electrolyte. The service life is 1-2 years, and you can continue to use it after replacing the fluorescent cap.

 
Application

It is widely used in urban sewage treatment, industrial wastewater treatment, surface water monitoring, aquaculture and other industries.


It can be matched with DUC2-DO single-parameter controller or connected with MCC100 five-parameter controller to realize the water quality monitoring of a set of water stations.

 

Model DUC2-DO-H-A
Software Version DRFN DO Analysis software V1.0
Sensor Input Compatible with all DRFN's DO Digital Sensors
Display Range DO Concentration DO concentration 0-50mg/L (or ppm), unit can be switched
Saturation 0-400%
TEMP -10~500℃ /14~932℉
Atmospheric Pressure 30-120kpa
Resolution DO Concentration 0.01 mg/L(or ppm)
Saturation 1%
TEMP 0.1℃/ 0.1℉
Salinity Compensation Range Input range 0.0001-99999ppt
Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output 2 settable 0/4~20mA current outputs, max load 1000Ω
Communication Method RS485 interface
MODBUS RTU
support JSON text data format
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Information Power off protection, parameters are retained indefinitely
Time/Data Record Record 14000 historical data
Record interval can be set between 1~999 minutes
Maintenance Records Last 100
Operating Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃, RH<55% ( no condensation, precision instruments)
Shell Material Enhanced ABS
Protection Grade IP66
Dimension 144*144*120 mm
Mounting Method Wall mounting, pipe clamping, panel (hole size 138*138 mm)
Electrical Interface The back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply 100~240VAC
Power Consumption About 7W
Weight About 800g

 

 

 

 

Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring 1

 

 

If you are interested in dissolved oxygen sensors, please contact us.

 

 

Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring 2
Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring 3
Do Probe Dissolved Oxygen Sensor ABS Water Station Monitoring 4
 
FAQ:


1. Is your company a manufacturer?
We are a manufacturer. We have our own R&D team and production workshop to ensure the quality and quantity of products.
 
2. How is the price of the product determined?
The price of the product is ordered according to the purchase quantity. If your purchase is large and will have a long-term cooperation, then we will give you a special price.
 
 
 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Ms. Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)