Send Message
Home ProductspH ORP Sensor

100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting

100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting
100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting
100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting 100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting 100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting 100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting 100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting

Large Image :  100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE
Model Number: ASP400-NYD05
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 5-15 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting

Description
Product Name: PH Sensor Model: ASP 400-NYD05
PH: 0~14pH Materials: PPS+Glass+Teflong
Working Temp.: 0.0~100.0℃ Working Pressure:: 0~6Bar
Reference System: Double Salt Bridge Reference Reference Electrode: Ag/AgCl
Electrolyte: Crystal Temp. Unit: NTC10K
High Light:

Pollution Resistant PH Probe Electrode

,

NTC10K Temperature Compensation PH Probe Sensor

,

analog signal pH acidity Probe

100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting

 

It is widely used in pH monitoring in water treatment, hydrological monitoring, wastewater treatment, swimming pools, fish ponds and fertilizers, chemicals, and biology.

 

Specification:

 Modle
 
  ASP 400-NYD05
PH Range
0~14pH 0.01pH
Shaft Material
PPS
Working TEMP
0~100℃
Reference System
double salt bridge
Reference Electrode
Ag/AgCl
Electrolyte
Crystal
Working Pressure
0~6Bar
Temperature Unit
NTC10K
Membrane
Porous Teflon
 Glass Head

 Transparent low impedance

 

Dimension
Diameter: 35mm Length: 260 mm ( include the cleaning cover)
Thread Size
1 inch NTP(both ends)
Lead Wire
Standard 5m
Ground
--
Cleaning
A protective cover with its own cleaning interface(Optional)
Application
Sewage

Please click the pH sensor user manual here:

ASP400T pH sensor technical data.pdf

 

Brief introduction:

◆ pH composite electrode, the body adopts high-performance ABS plastic shell encapsulation
◆ Sturdy structure, with installation threads at the beginning and end, easy to install;
◆ The electrode is equipped with a protective cover with its own cleaning interface;
◆ The indicator electrode adopts a low-impedance hemispherical glass head, which has high strength and is not easily broken;
◆ The reference adopts a large-area annular porous Teflon membrane, which has fast penetration speed, fast response, not easy to block, and easy to clean;
◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, and the reference is filled with saturated KCL+excess KCL crystal;

100℃ Resistance PPS PH Electrode NTC10K Temp. Compensation For Water Detecting 0

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

 

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

 

 

FAQ

1. What is themeasurement principle of this pH electrode?
A:
The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.


3. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.

 

4. What is the wire length of the pH electrode?
A: The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

 

5. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.