Product Details:
|
| Product Name: | Integrated Digital PH Sensor | Product Model: | DPH70 |
|---|---|---|---|
| Measuring Range: | 0~14 PH | Resolution: | 0.01 PH / 0.1℃ |
| Operating Environment: | 0~50℃ | Working Pressure: | 0~2Bar |
| Storage Temperature: | -15~65℃ | Material: | PPS |
| Protection Grade: | IP68 | Weight: | 150g |
| Highlight: | RS485 Digital PH Sensor,IP68 electronic ph probe,150g Digital PH Sensor |
||
Integrated Digital PH Sensor With RS485 Communication For Water Treatment
The DPH70 digital PH sensor can be connected to the DRFN’s digital PH/ORP controllers to measure the PH value. The digital PH probe has a pH measuring range of 0~14. The users can use it with online transmitters, DTUs, and portable instruments.
Advantages of The Digital PH Sensor
![]()
Applications of The Digital PH Sensor
General water purification, lakes and rivers, urban underground pipe networks and other environments.
Technical Parameter
| Product Name |
Digital PH Sensor |
|||
| Product Modle |
DPH70 |
|||
|
Measure Range |
0~14pH/0.0~50.0℃ |
|||
|
Resolution |
0.01 pH / 0.1℃ |
|||
|
Accuracy |
0.1% of the measuring range (or PH: ±0.02pH), take the larger one |
|||
|
Temperature Compensation |
Built-in temperature unit, automatic temperature compensation |
|||
|
Calibration |
Zero position/slope/deviation |
|||
|
Operating Temperature |
0°C ~ 50°C |
|||
|
Working Pressure |
0~2bars |
|||
|
Dimensions |
Diameter: 35 mm; Length: 260 mm (including cleaning protection cover) |
|||
|
Material |
PPS |
|||
|
Weight |
150g |
|||
|
Protection Grade |
IP68 |
|||
|
Installation Size |
One inch 1"NPT at the beginning and end of the installation thread; insertion depth 100 (including cleaning plug 115) |
|||
The Matching ORP Controllers Recommendation
| Product Name | PH Meter |
| Product Model | APX1-C2A/C2D |
| Software Version | DRFN PH Analysis software V1.0 |
| Sensor pH Input | Glass pH sensor |
| Sensor Temperature Input | PT1000 or NTC10K(B) |
| pH Range | -2~16pH |
| ORP Range | ± 2000mV |
| Temperature Range | -10~150℃ /14~302℉ |
| Resolution | 0.01pH / 1mV/ 0.1℃ |
| Accuracy | PH:±0.02 pH /ORP:±2 mV |
| Stability | 0.05% of the measurement range per 24 hours, no accumulation |
| Sensor Diagnosis | Display images on the screen |
| Analog Current Output | 2 settable 0/4~20mA active current loop output, maximum load 1000Ω |
| Relay Control | 2 settable SPST relays, maximum load 3A / 250VAC |
| Digital Communication | Two-wire RS485 interface, communication protocol: MODBUS RTU |
| Screen Display | 128 * 64 LCD |
| Operating Environment | 0~60℃, RH< 95% |
| Storage Environment | -20~70℃, RH < 55% |
| Power Supply | 100~240V AC or 18-36V DC |
| Power Consumption | 3 W |
| Shell Material | Enhanced ABS |
| Dimension | 100×100×120 mm (hole size 92*92mm) |
| Weight | 500g |
| Mounting Method | Panel installation |
| Electrical Interface | The back end of the instrument reserved 3 M12*1.5 gland |
Contact Person: Ms. Yuki Fu
Tel: +8615716217387