Product Details:
|
Product Name: | Chlorine Meter | Product Model: | ADS2-U3D-CL4.2 |
---|---|---|---|
Software Version: | DRFN Chlorine Analysis Software V1.0 | Display Range: | 0.00-200.00mg/L |
Resolution: | 0.001 Mg/L | Protection Grade: | IP66 |
Dimensions: | 144*144*120mm | Power Supply: | 18~36V DC |
Weight: | 800g | Power Consumption: | 10W |
Highlight: | 24V Chlorine Analyzers,10W Chlorine Meter,800g Chlorine Analyzers |
24V Chlorine Meter For Drinking Water Disinfection Measurement 800g
Brief Introduction
A complete set of the chlorine meter usually includes an ADS controller, a set of circulation systems for installing sensors, and special sensors corresponding to the measurement object. These main components can be installed on a customized backplane of the kit, or in an integrated instrument box, the user only needs to connect the inlet water sample pipe and the drain water pipe to complete the instrument installation.
Advantages Of The Chlorine Meter
1. Compatible with all DRFN membrane-covered ampere current sensors for disinfection residual chlorine.
2. Abundant output meets monitoring, control, and remote data transmission at the same time.
3. The communication standard is equipped with a two-wire RS485 interface, the communication protocol is MODBUS RTU. The instrument supports JSON text data format.
4. The display uses a 128*64 black and white graphic dot matrix screen, and the display backlight provides constant light and energy-saving mode selection.
5. The standard configuration of the universal chlorine meter is equipped with 2 settable 0/4~20mA active current loop outputs, and each current output allows the user to specify what measurement value it represents. At the same time, each output can define the range of output value corresponding to the maximum and minimum current value by itself, whether it is forward or reverse correspondence, it is all right. For long-distance output, current calibration can be used to ensure the accuracy of the output. The data accuracy of the current is 0.00025 (16 bits), and the maximum load is 1000Ω.
Applications Of The Chlorine Meter
Water treatment monitoring: domestic water, swimming pool, environmental protection sewage discharge monitoring;
Industrial process monitoring: circulating water, cooling water, aquaculture, papermaking, food, medicine manufacturing, etc.
Technical Parameters
Product Name | Chlorine Meter |
Product Model | ADS2-U3D-CL4.2 |
Software Version | DRFN Chlorine Analysis software V1.0 |
Display Range | 0.00-200.00mg/L |
Resolution | 0.001 mg/L |
Accuracy | Better than 0.15% of the measuring range |
Stability | 0.05% of the measuring range every 24 hours, no accumulation |
Repeatability | Better than 0.1% of the measuring range |
Relay Control | 2 settable SPST relays, the max. load 3A/250VAC |
Sensor Self-diagnosis | screen image and buzzer prompt |
Analog Current Output | 2 settable 0/4~20mA active current loop output max. load 1000Ω |
Communication Method | MODBUS RTU; support JSON text data format |
Display Screen | 128*64 LCD |
Time History/Data Record | Year/month/day/hour/min/second, record 14000 historical data |
Protection Grade | IP66 |
Operating Environment | 0~60℃, relative humidity less than 95% |
Storage Environment | -20~70℃, relative humidity less than 55% |
Shell Material | Enhanced ABS |
Dimensions | 144*144*120mm (hole size 138*138 mm) |
Mounting Method | Wall mounting, pipe clamping, panel installation |
Power Supply | 18~36V DC |
Weight | 800g |
The Matching Chlorine Sensors Recommendation
pH range: 6~8
Temperature range: 0~ 45℃
Connection: for mA-version 2-pole terminal, M12 male
Type | Measuring range: ppm | Resolution: ppm | Output signal | Power supply | Item number |
CL4.2MA0.5 | 0.01~ 0.50 | 0.01 | 4~20 mA | 12~30 VDC RL: 50~900 Ω | 3326240 |
CL4.2MA2 | 0.01~2.00 | 0.01 | 3326241 | ||
CL4.2MA5 | 0.01~5.00 | 0.01 | 3326242 | ||
CL4.2MA10 | 0.01~10.00 | 0.01 | 3326243 | ||
CL4.2MA20 | 0.01 ~20.00 | 0.01 | 3326244 | ||
CL4.2MA-100 | 0.1~100 | 0.1 | 3326245 | ||
CL4.2MA-200 | 0.1~ 200 | 0,1 | 3326246 | ||
CL4.2MA0.5-M12 | 0.01~0.50 | 0.01 | 4~20 mA | 12~30 VDC RL: 50~900 Ω | 3326250 |
CL4.2MA2-M12 | 0.01~2.00 | 0.01 | 3326251 | ||
CL4.2MA5-M12 | 0.01~5.00 | 0.01 | 3326252 | ||
CL4.2MA10-M12 | 0.01~10.00 | 0.01 | 3326253 | ||
CL4.2MA20-M12 | 0.01~20.00 | 0.01 | 3326254 | ||
CL4.2MA-100-M12 | 0.1~100 | 0.1 | 3326255 | ||
CL4.2MA-200-M12 | 0.1~200 | 0.1 | 3326256 |
Contact Person: Ms. Yuki Fu