Send Message
Home ProductsChlorine Analyzer

RS485 Chlorine Analyzers For Disinfectant Chlorine 24V

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

RS485 Chlorine Analyzers For Disinfectant Chlorine 24V

RS485 Chlorine Analyzers For Disinfectant Chlorine 24V
RS485 Chlorine Analyzers For Disinfectant Chlorine 24V
RS485 Chlorine Analyzers For Disinfectant Chlorine 24V RS485 Chlorine Analyzers For Disinfectant Chlorine 24V RS485 Chlorine Analyzers For Disinfectant Chlorine 24V RS485 Chlorine Analyzers For Disinfectant Chlorine 24V RS485 Chlorine Analyzers For Disinfectant Chlorine 24V

Large Image :  RS485 Chlorine Analyzers For Disinfectant Chlorine 24V

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE
Model Number: DUC2-CL-S-D
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable

RS485 Chlorine Analyzers For Disinfectant Chlorine 24V

Description
Product Name: Chlorine Transmitter Product Model: DUC2-CL-S-D
Software Version: DRFN Chlorine Analysis Software V1.0 Communication Method: RS485 MODBUS RTU
Protection Grade: IP66 Operating Environment: 0~60℃
Storage Environment: -20~70℃ Size: 144*144*120mm
Power Supply: 18~36V DC Power Consumption: 7W
Weight: 800g
High Light:

24V Chlorine Analyzers

,

24V chlorine transmitter

,

OTA Chlorine Analyzers

 

RS485 Chlorine Transmitter For The Measurement Of Disinfectant Chlorine 24V

 

 

Brief Introduction

  • Free chlorine is the most important disinfectant in water treatment due to its easy handling and strong disinfecting effect.

  • The DUC series disinfectant chlorine transmitter DUC2-CL-S-D used with the DRFN sensor helps to achieve safe and efficient disinfection by providing stable and fast measured values.

  • The CL controller is a digital universal controller for measuring the concentration of chlorine. Each controller will be pre-installed with a set of embedded software to adapt to different disinfectant sensors.

  • This digital chlorine analyzer is connected to the sensor. The sensor uploads the detected data in a special encrypted communication method. The DUC chlorine transmitter can collect high-precision data more stably. It is displayed on the display of the controller in real-time, which is very convenient for users to read.

  • The chlorine tester is equipped with a two-wire RS485 interface, the communication protocol is MODBUS RTU, and supports JSON text data format.

  • The instrument has 2 settable SPST multifunctional relays and 2 high-precision 0/4~20mA current outputs.

 

 

RS485 Chlorine Analyzers For Disinfectant Chlorine 24V 0

 

 

Advantages Of The Chlorine Transmitter

 

1. This disinfectant chlorine analyzer is equipped with RS485 Modbus RTU, RS485 Modbus RTU provides a stable and reliable communication solution suitable for industrial environments, enabling different types of equipment to communicate and control each other, which is beneficial to the integration and management of industrial automation systems.

RS485 allows multiple devices to be connected to the same bus and perform data transmission and control through serial communication protocols, making the integration between devices simpler and more flexible.

RS485 uses differential signal transmission, which can resist electromagnetic interference in industrial environments and ensure stable data transmission.

RS485 can support relatively long communication distances, allowing devices to be distributed in distant locations while maintaining reliable communication.

Modbus RTU is a widely used communication protocol. Its standardization allows devices from different manufacturers to communicate with each other, increasing the interoperability and compatibility of the devices.

 

2. The DUC disinfectant chlorine transmitter has the functions of clock and historical data recording, which can meet the higher management requirements of users for data.

 

3. 128*64 large-screen LCD display, Chinese and English language display, rich content, to meet the different needs of users.

 

4. The shell material of the instrument is reinforced ABS, the shell is strong, corrosion-resistant, and wear-resistant. The overall size of the DUC chlorine gauge is 144*144*120mm, and the user can choose a variety of installation methods such as wall-mounted installation, pipe clamping installation, and panel installation.

 

5. The controller has a power-off protection configuration, and the parameters can be kept indefinitely.

 

 

Applications Of The Chlorine Transmitter

 

It is applied to online monitoring of chlorine concentration in drinking water and industrial process water disinfection and sterilization process, sewage treatment and circulating cooling water treatment, and can also be used in swimming pools and other places where chlorine concentration needs to be measured.

 

 

Technical Parameters

 

Product Name

Disinfectant Chlorine Transmitter

Product Model

DUC2-CL-S-D

Software Version

DRFN chlorine Analysis software V1.0

Display Range

0.01mg/L~100g/L

Resolution

0.01mg/L

Relay Control

2 settable SPST relays max. load 3A/250VAC

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

Two-wire RS485 interface; MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data

Protection Level

IP66

Operating Environment

0~60℃, relative humidity less than 95% (no condensation)

Storage Environment

-20~70℃, relative humidity less than 55% (no condensation)

Shell Material

Enhanced ABS

Size

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel mounting

Power Supply

18-36V DC

Weight

800g

Power Consumption

7W

 

 

RS485 Chlorine Analyzers For Disinfectant Chlorine 24V 1

 

 

The Matching DRFN Chlorine Sensors Recommendation

 

  • Model: CL4.2
  • pH range: 6~8

  • Pressure range: 0~1 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 30 seconds
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U and semipermeable membrane
  • Applications: Fresh water free of surfactants and with constant pH

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CL4.2H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 V DC

20~56 mA

3326225
CL4.2N-M0c 0.05~20.00 0.01 3326226
CL4.2L-M0c 0.5~200.0 0.1 3326227

 


  • Model: CC1
  • pH range: 4~12

  • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
  • Applications: Fresh water and seawater; surfactants are tolerated in part; a special electrolyte is used for seawater

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CC1H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 V DC

20~56 mA

3426610
CC1N-M0c 0.05~ 20.00 0.01 3426611

 


  • Model: CS4
  • pH range: 4~9

  • Pressure range: 0~3 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
  • Applications: Fresh water and sea water at 10 µS/cm~50 mS/cm, surfactants are partially tolerated

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CS4H-M0c 0.005~2.000 0.001 ModBus RTU

9~30 V DC

20~56 mA

3426360
CS4N-M0c 0.05~20.00 0.01 3426361
CS4L-M0c 0.5~200.0 0.1 3426362

 


  • Model: CP3
  • pH range: 4~12

  • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
  • Applications: Swimming pool, drinking and seawater, surfactants are partially tolerated; special electrolyte for the use in sea water

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CP3H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 V DC

20~56 mA

3326960
CP3N-M0c 0.05~20.00 0.01 3326961

 


  • Model: CN1.1
  • pH range: 6.5~9

  • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 195 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous membrane
  • Applications: Check for the absence of chlorine in water

 

Type: Measuring range: ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CN1.1H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 VDC

20~56 mA

3326610
CN1.1H-M0c 3326612

 


 

  • Model: AS2 AS3
  • pH range: 5~9

  • Pressure range: 0~8 bar, no pressure surges or fluctuations
  • Temperature range: 0~50℃(AS2), 0~70℃ (AS3)
  • Integrated automatic temperature compensation
  • Response time: T90 about 30s
  • Flow rate: about 30 l/h
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U (AS2), PEEK (AS3)
  • Applications: Fresh water, especially drinking water, up to max. 70℃

 

Type:

(up to 50℃)

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
AS2H-CL-M0c 0.005~2.00 0.001 Modbus RTU

9~30 V DC

20~56 mA

3426770
AS2N-CL-M0c 0.03~10.00 0.01 3426771

 

Type:

(up to 70℃)

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
AS3H-CL-M0c 0.005~2.00 0.001 Modbus RTU

9~30 V DC

20~56 mA

3426720
AS3N-CL-M0c 0.03~10.00 0.01 3426721

 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Ms. Yuki Fu

Tel: +8615716217387