Send Message
Home ProductsChlorine Analyzer

Disinfectant Electronic Chlorine Meter 24V Two SPST

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

Disinfectant Electronic Chlorine Meter 24V Two SPST

Disinfectant Electronic Chlorine Meter 24V Two SPST
Disinfectant Electronic Chlorine Meter 24V Two SPST
Disinfectant Electronic Chlorine Meter 24V Two SPST Disinfectant Electronic Chlorine Meter 24V Two SPST Disinfectant Electronic Chlorine Meter 24V Two SPST Disinfectant Electronic Chlorine Meter 24V Two SPST

Large Image :  Disinfectant Electronic Chlorine Meter 24V Two SPST

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE
Model Number: DUC2-CL-H-D
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable

Disinfectant Electronic Chlorine Meter 24V Two SPST

Description
Product Name: Disinfectant Chlorine Meter Product Model: DUC2-CL-H-D
Software Version: DRFN Chlorine Analysis Software V1.0 Protection Grade: IP66
Display Screen: 128*64 LCD Shell Material: Enhanced ABS
Operating Environment: 0~60℃ Storage Environment: -20~70℃
Size: 144*144*120mm Power Supply: 18~36V DC
Power Consumption: 7W Weight: 800g
High Light:

24V electronic chlorine meter

,

24V residual chlorine analyzer

,

Two SPST electronic chlorine meter

 

24V Two SPST Disinfectant Chlorine Meter For The Measurement Of Chlorine

 

 

Brief Introduction

  • Residual chlorine means that after chlorine is put into the water, in addition to the bacteria, microorganisms, organics, inorganics, etc. in the water, a part of the chlorine is consumed, and a part of the chlorine is left. This part of the chlorine is called residual chlorine. Residual chlorine can be divided into chemical residual chlorine and free residual chlorine. Total residual chlorine is the sum of chemical residual chlorine and free residual chlorine.

  • DUC series disinfectant chlorine meter is a digital universal controller for measuring the concentration of chlorine. Each controller will be pre-installed with a set of embedded software to adapt to different disinfectant sensors.

  • Users can use the operation panel in front of the DUC controller to calibrate the sensor, set the output parameters, and routine maintenance, which is convenient and quick.

  • The enclosure protection grade of this meter is IP66. This material can effectively isolate the pollution and corrosive gas from the external environment.

  • The instrument has 2 SPST multifunctional relays that can be set and 2 high-precision 0/4~20mA current outputs.

 

Disinfectant Electronic Chlorine Meter 24V Two SPST 0

Advantages Of The Chlorine Meter

  • The DUC disinfectant chlorine analyzer has the functions of clock and historical data recording, which can meet the higher management requirements of users for data.
  • The CL meter has a 3.2-inch display screen and uses a 128*64 black and white graphic dot matrix LCD liquid crystal display, with reasonable interface settings and simple operation.

  • The shell material of the instrument is reinforced ABS, the shell is strong, corrosion-resistant and wear-resistant. The overall size of the DUC free chlorine meter is 144*144*120mm, and the user can choose a variety of installation methods such as wall-mounted installation, pipe clamping installation, and panel installation.

  • The controller has a power-off protection configuration, and the parameters can be kept indefinitely.

 

 

Applications Of The Chlorine Meter

 

It is applied to online monitoring of chlorine concentration in drinking water and industrial process water disinfection and sterilization process, sewage treatment and circulating cooling water treatment, and can also be used in swimming pools and other places where chlorine concentration needs to be measured.

 

 

Technical Parameters

 

Product Name

Disinfectant Chlorine Meter

Product Model

DUC2-CL-H-D

Software Version

DRFN chlorine Analysis software V1.0

Display Range

0.01mg/L~100g/L

Resolution

0.01mg/L

Relay Control

2 settable SPST relays max. load 3A/250VAC

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

Two-wire RS485 interface; MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD, adjustable backlight mode

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data

Protection Level

IP66

Operating Environment

0~60℃, relative humidity less than 95% (no condensation)

Storage Environment

-20~70℃, relative humidity less than 55% (no condensation)

Shell Material

Enhanced ABS

Size

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel mounting

Power Supply

18-36V DC

Weight

800g

Power Consumption

7W

 

 

Disinfectant Electronic Chlorine Meter 24V Two SPST 1

 

 

The Matching DRFN Chlorine Sensors Recommendation

 

  • Model: CL4.2
  • pH range: 6~8

  • Pressure range: 0~1 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 30 seconds
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U and semipermeable membrane
  • Applications: Fresh water free of surfactants and with constant pH

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CL4.2H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 V DC

20~56 mA

3326225
CL4.2N-M0c 0.05~20.00 0.01 3326226
CL4.2L-M0c 0.5~200.0 0.1 3326227

 


  • Model: CC1
  • pH range: 4~12

  • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
  • Applications: Fresh water and seawater; surfactants are tolerated in part; a special electrolyte is used for seawater

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CC1H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 V DC

20~56 mA

3426610
CC1N-M0c 0.05~ 20.00 0.01 3426611

 


 

  • Model: CS4
  • pH range: 4~9

  • Pressure range: 0~3 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
  • Applications: Fresh water and sea water at 10 µS/cm~50 mS/cm, surfactants are partially tolerated

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CS4H-M0c 0.005~2.000 0.001 ModBus RTU

9~30 V DC

20~56 mA

3426360
CS4N-M0c 0.05~20.00 0.01 3426361
CS4L-M0c 0.5~200.0 0.1 3426362

 


 

  • Model: CP3
  • pH range: 4~12

  • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
  • Applications: Swimming pool, drinking and seawater, surfactants are partially tolerated; special electrolyte for the use in sea water

 

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CP3H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 V DC

20~56 mA

3326960
CP3N-M0c 0.05~20.00 0.01 3326961

 


  • Model: CN1.1
  • pH range: 6.5~9

  • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
  • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
  • Integrated automatic temperature compensation
  • Response time: T90 about 2min
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 195 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, PEEK, stainless steel 1.4571, microporous membrane
  • Applications: Check for the absence of chlorine in water

 

Type: Measuring range: ppm

Resolution:

ppm

Output signal: Power supply: Item number:
CN1.1H-M0c 0.005~2.000 0.001 Modbus RTU

9~30 VDC

20~56 mA

3326610
CN1.1H-M0c 3326612

 


 

  • Model: AS2 AS3
  • pH range: 5~9

  • Pressure range: 0~8 bar, no pressure surges or fluctuations
  • Temperature range: 0~50℃(AS2), 0~70℃ (AS3)
  • Integrated automatic temperature compensation
  • Response time: T90 about 30s
  • Flow rate: about 30 l/h
  • Shaft length: standard 175 mm

  • Connection: Modbus RTU with M12 male
  • Material: PVC-U (AS2), PEEK (AS3)
  • Applications: Fresh water, especially drinking water, up to max. 70℃

 

Type:

(up to 50℃)

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
AS2H-CL-M0c 0.005~2.00 0.001 Modbus RTU

9~30 V DC

20~56 mA

3426770
AS2N-CL-M0c 0.03~10.00 0.01 3426771

 

Type:

(up to 70℃)

Measuring range:

ppm

Resolution:

ppm

Output signal: Power supply: Item number:
AS3H-CL-M0c 0.005~2.00 0.001 Modbus RTU

9~30 V DC

20~56 mA

3426720
AS3N-CL-M0c 0.03~10.00 0.01 3426721

 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Ms. Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)