Product Details:
|
Product Name: | Chlorine Dioxide Sensor | Product Model: | Chlorine Dioxide Sensor CD7 |
---|---|---|---|
Indicator: | Chlorine Dioxide | Temperature Range: | 0 ~ 50℃ |
PH Range: | 1 ~ 11 | Pressure Range: | 0 ~ 1bar,no Pressure Surges Or Fluctuations |
Response Time: | T90 90sec. | Flow Rate: | 30L / H,low Flow-dependence |
Highlight: | 220mm Water Quality Sonde,30L H chlorine dioxide detector,30L H Water Quality Sonde |
50℃ Chlorine Dioxide Sensor Water Quality Sensor Surfactant Resistant Membrane
Descriptions
The chlorine dioxide sensor CD7 is for the measurement of chlorine dioxide. The water quality sensor is amperometric 2-electrode system with surfactant-resistant membrane. The interference of the measurement is O3, Cl2 does not interfere. The size of the sensor is standard 175 mm, and up to 220 mm in length (mA-Version).
If you want to calibrate the sensor, at the controller, via analytical chlorine dioxide determination by DPD-1 method. The material of the sensor is PVC-U, stainless steel 1.4571, semipermeable membrane. The Pressure range of the chlorine dioxide sensor is 0 ~ 1bar. The measuring water temperature is from 0℃ to 50℃. No ice crystal is allowed in the measuring water.
Specifications
Product Name | Chlorine dioxide sensor water quality sonde |
Product Model | Chlorine dioxide sensor CD7 |
pH Range | 1 ~ 11 |
Pressure Range | 0 ~ 1bar |
Temperature Range |
0 ~ 50℃ |
Flow Rate | 30 l/h low flow-dependence |
Response Time
|
T90 90s
|
Connection |
mA - version 2-pole terminal, M12 male or Modbus RTU with M12 male |
Shaft Length |
Standard 175 mm, and up to 220 mm in length (mA - Version) |
temperature Compensation
|
Integrated automatic
|
The chlorine dioxide sensor CD7 is amperometric 2-electrode system with the surfactant-resistant membrane. Membrane-covered amperometric sensors are capable of providing details on the effectiveness of free chlorine under the conditions pertaining.
Applications Of The Chlorine Dioxide Sensor
Scope Of Supply
Water quality sensor chlorine dioxide sensor CD7: sensor, membrane cap, electrolyte.
Ordering Data:
Type |
Measuring range(ppm) |
Resolution(ppm) |
Output signal |
Power supply |
Item number |
CD7H-M0c |
0.005 ~ 2.000 |
0.001 |
Modbus RTU
|
9 ~ 30 V DC
|
3226620 |
CD7N-M0c |
0.05 ~ 20.00 |
0.01 |
3226621 |
||
CD7L-M0c | 0.5 ~ 200.0 | 0.1 | 3226622 | ||
CD7MA0.5 |
0 ~ 0.50 |
0.01 |
4 ~ 20 mA
|
12 ~ 30 VDC
|
3326045 |
CD7MA2 |
0 ~ 2.00 |
0.01 |
3326046 |
||
CD7MA5 |
0 ~ 5.00 |
0.01 |
3326047 |
||
CD7MA10 | 0 ~ 10.00 | 0.01 | 3326048 | ||
CD7MA20 | 0 ~ 20.00 | 0.01 | 3326086 | ||
CD7MA200 | 0.5 ~ 200.0 | 0.1 | 3326104 | ||
CD7MA0.5-M12 |
0 ~ 0.50 |
0.01 | 4 ~ 20 mA |
12 ~ 30 VDC
|
3226610 |
CD7MA2-M12 |
0 ~ 2.00 |
0.01 |
3226611 |
||
CD7MA5-M12 |
0 ~ 5.00 |
0.01 |
3226612 |
||
CD7MA10-M12 | 0 ~ 10.00 | 0.01 | 3226613 | ||
CD7MA20-M12 | 0 ~ 20.00 | 0.01 | 3226614 | ||
CD7MA200-M12 | 0.5 ~ 200.0 | 0.1 | 3226615 |
If you are interested in the water quality sonde chlorine dioxide sensor CD7, please contact us.
Contact Person: Ms. Yuki Fu
Tel: +8615716217387