Product Details:
|
Product Name: | Online PH ORP Tester | Relay Control: | 2 SPST Relays |
---|---|---|---|
Sensor Input TEMP: | PT1000 Or NTC10K | Supply Voltage: | DC Power Supply 18~36VDC |
Range: | ±2000mV | Resolution: | 0.01PH |
Accuracy: | PH: ±0.02pH / ORP: ±2mV | Measure Temperature: | 10~150℃ / 0.1℃(14~302℉ / 0.1℉) |
Operating Temperature: | 0-60℃ | Instrument Size: | 144*144*120mm |
Instrument Weight: | 800g | Power Consumption: | 5W |
Highlight: | 800g PH ORP Analyzers,2 SPST relays ph orp tester,2 SPST relays PH ORP Analyzers |
-2~16pH 1000 Ω Two SPST Relays Online PH ORP Tester For Aquaculture Water Treatment
Brief introduction
Usually the PH tester can be connected to the ORP electrode to detect the redox charge of the aqueous solution and is usually labeled PH/ORP tester
ORP measurements are not controlled by temperature, so ORP electrodes do not require temperature compensation. In case the oxidation level is high (the ORP value is high), platinum electrodes are recommended, and conversely gold electrodes are recommended. Both inert electrodes are usually used as reference electrodes for ORP measurements.
The PH/ORP tester can be connected to a variety of traditional PH/T or ORP combination electrodes. It has the patented temperature detection and temperature drift compensation technology
Applications of Online PH ORP tester
1 Water treatment monitoring: drinking water surface water quality groundwater environmental sewage discharge monitoring urban drainage network monitoring
2 Industrial process monitoring and dosing control treatment: chemical petroleum paper food medicine electroplating PCB manufacture
Technical Parameters of Online PH ORP tester
Model | APX2-C3D | |
Software version | DRFN PH Analysis software V1.0 | |
Sensor Input | PH | Glass PH sensor |
ORP | Redox sensor (platinum / gold sensor) | |
TEMP | PT1000 or NTC10K | |
Range/ resolution |
PH | -2~16pH / 0.01pH |
ORP | ±2000mV / 1mV | |
Measure temperature | -10~150℃ / 0.1℃(14~302℉ / 0.1℉) | |
Performance | Accuracy | 0.1% of span or PH: ±0.02pH /ORP: ±2mV, select larger one. |
Stability | 0.05% of span every 24 hours, no accumulation. | |
Repeatability | Better than 0.1% of span | |
Relay control | 2 SPST relays: PH/OPR alarm, water temperature alarm, electrode cleaning cycle control; the maximum load is 3A/250VAC. | |
Analog current output | Two ways 0/4 ~ 20mA current; accuracy 0.00025 (16 bits); Maximum load 1000 Ω. | |
Communication mode
|
Two-wire RS485 interface, communication protocol: MODBUS RTU Supports JSON (JavaScript Object Notation) text data formats. |
|
Display Language
|
128 x 64 dots LCD ; English / Chinese / Other languages | |
Time history/ data record |
Record in years, months, dates, hours, minutes and seconds, Keep 14,000 historical measurements and last 500 maintenance data T |
|
Overall dimensions | 144*144*120mm Panel Hole dimension 138*138mm | |
Power | DC power supply 18~36VDC | |
Power consumption | 5W | |
Instrument weight | About 800g |
Advantage of Online PH ORP tester
The PH/ORP tester can not only make temperature compensation for the test sample by accessing the temperature electrode, but also monitor the instrument's environmental operating temperature (instrument temperature self-test) in real time, and when the instrument's operating temperature changes, the instrument compensates for the hardware changes caused by temperature drift, making the test results more accurate, which is a patented technology.
The PH ORP tester is an online tester with rich output configuration, suitable for high-demand monitoring and control applications.
The PH ORP instruments are available in a variety of dimensions to meet a wide range of installation methods, while also providing the necessary installation accessories. The PH ORP tester intelligently diagnoses glass electrodes and prompts field engineers for electrode maintenance or replacement.
The PH ORP tester works accurately in years, months, dates, hours, minutes and seconds, it records the measurement data on time to form a consultable historical data. The PH ORP instrument can record up to 14,000 historical measurements. The recording interval is freely set by the user. User maintenances are also recorded and the last 500 maintenance data are saved to help us find and analyze the cause of the instrument's abnormal operation.
More picture for Online PH ORP tester
Contact Person: Ms. Yuki Fu
Tel: +8615716217387