                        Product Details:
                                                     
                
 
  | 
                    
| Product Name: | Industrial Online PH ORP Analyzer | Range: | -2~16 PH / ±2000mV | 
|---|---|---|---|
| Resolution: | 0.01pH / 1mV | Temperature Measuring Range: | -10~150℃(14~302℉) | 
| Screen: | 128*64 Dots | Operating Temperature: | 0-60℃ | 
| Supply Voltage: | 100~240VAC | Instrument Size: | 100*100*120mm | 
| Installation: | Panel Installation | Protection Level: | IP66 | 
| Highlight: | 500g ph orp meter,IP66 hydro ph orp,2000mV ph orp meter | 
					||
±2000mV IP66 Industrial Online PH ORP Analyzer For Continuous Wastewater Monitoring
Brief introduction
PH/ORP analyzer can be connected to a variety of traditional pH/T or ORP combination electrodes. It has the patented temperature detection and temperature drift compensation technology.
PH/ORP analyzer offers a wide range of output configurations to accommodate the different needs of cost and performance.
PH/ORP analyzer are available in a variety of dimensions to meet a wide range of installation methods, while also providing the necessary installation accessories.
![]()
Applications of Online PH ORP analyzer
Industrial process monitoring: chemical,petroleum,paper,food,medicine,electroplating,PCB manufacture.
Technical Parameters of Online PH ORP analyzer
| Model | APX1-C1A | 
| Software Version | DRFN PH Analysis software V1.0. | 
| Sensor Input PH | Glass PH sensor | 
| Sensor Input ORP | Redox sensor (platinum/gold sensor) | 
| Sensor Input TEMP | NTC10K | 
| Range/ Resolution PH | 2~16pH / 0.01pH | 
| Range/ Resolution ORP | ±2000mV / 1mV | 
Range/ Resolution Measure Temperature  | -10~150℃ / 0.1℃(14~302℉ / 0.1℉) | 
| Performance Accuracy | 0.1% of span or PH: ±0.02pH /ORP: ±2mV, select larger one. | 
| Performance Stability | 0.05% of span every 24 hours, no accumulation. | 
| Performance Repeatability | Better than 0.1% of span | 
| Relay Control | 2 SPST relays can be set: PH/OPR alarm, water temperature alarm, electrode cleaning cycle control; the maximum load is 3A/250VAC. | 
| Analog Current Output | 0/4 ~ 20mA ; Current accuracy 0.00025 (16 bits); Maximum load 1000 Ω. | 
| Working Environment | Operating 0~60 ºC; storage -20~70 ºC; relative humidity < 95% RH (no condensation). | 
| Overall Dimensions | 100*100*120mm Panel hole dimension 92*92mm | 
| Power | AC power supply 100~240VAC | 
| Power Consumption | 3W | 
| Instrument Weight | About 500g | 
More picture of Online PH ORP analyzer
 
![]()
Contact Person: Ms. Yuki Fu
Tel: +8615716217387