Product Details:
|
Product Name: | IP66 PH ORP Analyzer | Sensor Input Temperature: | PT1000 Or NTC10K |
---|---|---|---|
Range: | -2~16pH / ±2000mV | Resolution: | 0.01pH / 1mV |
Measure Temperature: | -10~150℃ (14~302℉ ) | Power Consumption: | 3W |
Storage Temperature: | -20~70 ºC | Supply Voltage: | 100~240VAC |
Instrument Size: | 100*100*120mm | Instrument Weight: | 500g |
Highlight: | IP66 PH ORP Analyzer,100 x 100mm ph orp tester,2000mV PH ORP Analyzer |
IP66 ±2000mV OEM Online PH ORP Analyzer For Industrial Processing Water Treatment
Brief introduction
The PH ORP analyzer is regular PH/ORP online tester with rich output configuration, suitable for high-demand monitoring and control applications.
PH/ORP analyzer can be connected to a variety of traditional pH/T or ORP combination electrodes. It has the patented temperature detection and temperature drift compensation technology.
Applications of Online PH ORP analyzer
1 Water treatment monitoring: drinking water,surface water,ground water,environmental sewage discharge monitoring,urban drainage network monitoring.
2 Industrial process monitoring and dosing control treatment: chemical,petroleum,paper,food,medicine,electroplating,PCB manufacture.
Technical Parameters of Online PH ORP analyzer
Model | APX1-C2A |
Software Version | DRFN PH Analysis software V1.0 |
Sensor Input PH | Glass PH sensor. |
Sensor Input ORP | Redox sensor (platinum/gold sensor) |
Sensor Input TEMP | PT1000 or NTC10K |
Range/ Resolution PH | -2~16pH / 0.01pH |
Range/ Resolution ORP | ±2000mV / 1mV |
Range/ Resolution Measure Temperature | -10~150℃ / 0.1℃(14~302℉ / 0.1℉) |
Performance Accuracy | 0.1% of span or PH: ±0.02pH /ORP: ±2mV, select larger one. |
Performance Stability | 0.05% of span every 24 hours, no accumulation. |
Performance Repeatability | Better than 0.1% of span |
Relay Control | 2 SPST relays: PH/OPR alarm, water temperature alarm, electrode cleaning cycle control; the maximum load is 3A/250VAC. |
Analog Current Output | Two ways 0/4 ~ 20mA current; accuracy 0.00025 (16 bits); Maximum load 1000 Ω. |
Communication Mode | Two-wire RS485 interface, communication protocol: MODBUS RTU |
Display Language | 128 x 64 dots; English / Chinese / Other languages |
Working Environment | Operating 0~60 ºC; storage -20~70 ºC; relative humidity < 95% RH (no condensation). |
Overall Dimensions | 100*100*120mm Panel hole dimension 92*92mm |
Power | AC power supply 100~240VAC |
Power Consumption | 3W |
Instrument Weight | About 500g |
Advantage of Online PH ORP analyzer
Two active current ring outputs of 0/4 ~ 20mA can be set in PH ORP analyzer, allowing the user to specify the measurement: pH ORP or corresponding temperature to represent. At the same time, each output can define its own maximum /minimum current value to correspond to the range of output values, whether positive or reverse. The accuracy of the output can be guaranteed by long-distance current calibration. The data accuracy of the current is 0.00025 (16 bits) and the maximum load is 1000 Ω.
Recommend enclosure panel installation. The back end of the PH ORP analyzer reserves 3 M12 x 1.5 electrical connectors, and the cross-line diameter is 3~6.5mm.
The system displays sensor measurement data and other dynamic data of the instrument in at least Chinese and English languages. According to the observation habit, the user can choose whether the displayed data is timely or smooth by adjusting the display rate.
More pictures of Online PH ORP analyzer
Contact Person: Ms. Yuki Fu
Tel: +8615716217387