Suzhou, China — Daruifuno has introduced the DEC890 digital conductivity sensor, a graphite two-electrode instrument engineered for continuous online water monitoring where mains power is unavailable or expensive. The sensor operates on a DC 9~36V wide voltage input and draws only about 0.2W, a power budget that allows it to run from a small solar panel, a 12V or 24V battery bank, or the same low-capacity DC bus that feeds a remote data logger.
Remote water monitoring projects rarely fail because of the measurement technology. They fail because the power system cannot support the instruments. A conductivity probe that needs a dedicated power supply forces integrators to add converters, larger batteries and bigger solar arrays, and every extra component becomes a maintenance item in the field.
The DEC890 removes that constraint. Two parallel graphite plates are immersed in the water, a driving voltage is applied across them, and the conductivity of the solution is calculated from the current flowing between the plates. Graphite is used instead of metal because it substantially reduces polarization, the electrochemical effect that causes metallic electrodes to drift during long immersion. The result is a stable signal with an accuracy of ±1% of the selected measuring range and resolution down to 0.01uS/cm.
| Measuring principle | Graphite two-electrode cell |
|---|---|
| Measuring ranges | 0~20uS/cm, 20~200uS/cm, 200~2000uS/cm, 2~10mS/cm |
| Resolution | 0.01uS/cm, 0.1uS/cm, 1uS/cm |
| Accuracy | ±1% of measuring range |
| Power supply | DC 9~36V, about 0.2W |
| Communication | RS485 MODBUS-RTU, address 17, 9600bps, 8N1 |
| Protection | IP68, 0~1 Bar, 0~50°C |
| Housing | Stainless steel 316 + POM, 37mm diameter, 261mm length |
Solar powered surface water stations, battery backed wells, hilltop reservoirs, irrigation canals and decentralized sewage treatment plants all share the same profile: no mains power, infrequent maintenance visits and an expectation that the data will keep flowing through the rainy season. The DEC890 is specified for exactly these sites.
Offset calibration, factor calibration, two-point calibration and multi-point calibration up to five points are supported. In routine service, two samples of known conductivity are enough to establish the offset and factor values. When the measuring head is replaced or the range changes, standards of 84uS/cm, 146uS/cm, 1413uS/cm and 12880uS/cm can be measured in sequence, with each reference value written directly to its Modbus register. A dedicated reset register returns the sensor to factory calibration in a single command, which simplifies site handover and auditing.
The DEC890 is available with a standard 10-meter shielded cable and M16 connector; customized cable lengths are offered for deep wells and long pipeline runs. Both ends of the 37mm body are machined with 1-inch NPT threads, so the same sensor fits side wall brackets, top flanges, pipeline tees, submerged mounts and flow-through housings. Buyers can specify the measuring range, cable length and connector type at the time of order, and the factory pre-configures the Modbus address and communication parameters before shipment.
For technical documentation, pricing and sample requests, contact the Daruifuno sales team and quote model DEC890 together with the required measuring range.