Send Message
Home ProductspH ORP Sensor

Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water

Certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
China Suzhou Delfino Environmental Technology Co., Ltd. certification
I'm Online Chat Now

Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water

Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water
Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water

Large Image :  Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE, ISO
Model Number: ASP100V-VYD01
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 5- 20 work days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water

Description
Product Name: Glass PH Sensor Application: Clean Water
PH: 0~14pH Resolution: 0.01pH
Working Temperature: 0~100℃ Working Pressure:: 0~4bar
Reference System: Double Salt Bridge Reference Electrode: Ag/AgCl
Temperature Unit: Without Size: Diameter 12mm/Length120mm
High Light:

Sewage PH ORP Sensor

,

Analog Signal PH ORP Probe

,

1 Inch NTP PH ORP Electrode

 

Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water


 

A pH electrode, the part of a pH meter that is in contact with the solution being measured, is a device used to determine the potential value of a specific ion of the solution. The pH probe sensor is a pH composite electrode with a glass shell. Glass housing is more corrosion resistant than plastic housing.


The glass head of the pH probe sensor is blue low-impedance hemispherical. It has high strength and does not break easily, it helps enhance the accuracy of measurement.


The reference electrode of the pH probe sensor is Ag/AgCl, reference filled saturated KCL + excess KCL crystals for long service life. It has the advantage of low maintenance and suitable for online measurements in demanding applications.


The reference system is a double salt bridge design, and the ceramic porous cores have a smooth response, no drift in potential, and good stability. The pH probe is equipped with standard 3m low noise leads.

 

Specification:

 

Product Name pH sensor
Product Model ASP100V-VYD01
pH Range 0~14pH
Resolution 0.01pH
Shaft Material Glass
Working TEMP 0~100℃
Reference System double salt bridge
Reference Electrode Ag/AgCl
Electrolyte Gel
Working Pressure 0~4Bar
Temperature Unit ——
Membrane Ceramic hole
Glass Head Blue low impedance
Dimension Diameter: 12mm Length:120mm
Thread Size ——
Lead Wire Standard 3m
Ground ——
Cleaning ——
Application Clean water

More details please refer to catalog here:

Daruifuno Catalog.pdf

 

Brief introduction:

  • Glass shell pH composite electrode;

  • Blue low impedance hemispherical glass head, high strength, not easy to break;

  • The reference is ceramic hole shape core, it has the characteristics of smooth response, no potential drift and good stability;

  • The reference system is Ag/AgCl, double salt bridgefilled with KCl colorless high temperature gel;

  • The reference electrolyte is saturated KCL+ excess KCL crystal, the service life is long;

  • The ASP101 pH electrode can not only be used for drinking water but also in wastewater, sewage and other industria applications.

Analog Signal Glass PH Sensor With High Temperature Resistance For Pure Water 0

Aplication: Pure water monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

 

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

 

FAQ

1. What is themeasurement principle of this pH electrode?
A:
The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.


3. How to judge the pH of the solution?
A: If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7


4. What is the wire length of the pH electrode?
A: The lead wire of this electrode is 3m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

 

5. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.
 

 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)