Digital Fluorescence Method 18~36VDC  Dissolved Oxygen Controller For Waste Water Digital Fluorescence Method 18~36VDC  Dissolved Oxygen Controller For Waste Water Digital Fluorescence Method 18~36VDC  Dissolved Oxygen Controller For Waste Water Digital Fluorescence Method 18~36VDC  Dissolved Oxygen Controller For Waste Water Digital Fluorescence Method 18~36VDC  Dissolved Oxygen Controller For Waste Water

Large Image :  Digital Fluorescence Method 18~36VDC Dissolved Oxygen Controller For Waste Water

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE, ISO
Model Number: DUC2-DO-H-D
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 5-25 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

Digital Fluorescence Method 18~36VDC Dissolved Oxygen Controller For Waste Water

Description
Product Name: DO Meter DO Concentration: 0-50mg/L
Saturation: 0-400% Temperature Range: -10~500℃ /14~932
Atmospheric Pressure: 30-120kpa Relay Control: 2 Settable SPST Relays
Analog Current Output: 2 Settable 0/4~20mA Communication Metho: RS485 Interface
Time/Data Record: 14000 Historical Data Protection Grade: IP66
Highlight:

Switch Control Dissolved Oxygen Controller

,

Low Alarm Dissolved Oxygen analyzer

,

Aquariums Dissolved Oxygen Transmitter

 

Digital Fluorescence Method 18~36VDC Dissolved Oxygen Controller For Waste Water

 

Dissolved oxygen (abbreviated as DO) refers to the content of oxygen dissolved in water, usually in units of ppm or mg/l, ppb or ug/l.

 

Specification:

Model DUC2-DO-H-D
Software Version DRFN DO Analysis software V1.0
Sensor Input Compatible with all DRFN's DO Digital Sensors
Display Range DO Concentration DO concentration 0-50mg/L (or ppm), unit can be switched
Saturation 0-400%
TEMP -10~500℃ /14~932℉
Atmospheric Pressure 30-120kpa
Resolution DO Concentration 0.01 mg/L(or ppm)
Saturation 1%
TEMP 0.1℃/ 0.1℉
Salinity Compensation Range Input range 0.0001-99999ppt
Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output 2 settable 0/4~20mA current outputs, max load 1000Ω
Communication Method

RS485 interface

MODBUS RTU

support JSON text data format

OTA ——
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Information Power off protection, parameters are retained indefinitely
Time/Data Record

Record 14000 historical data

Record interval can be set between 1~999 minutes

Maintenance Records Last 100
Operating Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃, RH<55% ( no condensation, precision instruments)
Shell Material Enhanced ABS
Protection Grade IP66
Dimension 144*144*120 mm
Mounting Method Wall mounting, pipe clamping, panel (hole size 138*138 mm)
Electrical Interface The back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply 18~36VDC
Power Consumption About 7W
Weight About 800g

Please click the user manual of DO controller here:

DUC2-DO User Manual.pdf

 

Features& Advantages

● Compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography;

● Automatic compensation for air pressure display;

● The working status of the sensor can be queried, including reading the serial number;

● OTA download technology as a smart configuration option for the instrument;

● Time and historical data recording function;

● 3.2-inch large LCD screen;

● User-friendly Chinese and English language interface;

● Password can be set to prevent misoperation;

● 2 SPST multi-function and settable relays;

● Two 0/4~20mA active current loop outputs;

● RS485 interface, Modbus RTU communication protocol;

● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

● Support a variety of installation methods.

Digital Fluorescence Method 18~36VDC  Dissolved Oxygen Controller For Waste Water 0

Aplication:
◇ Sewage
◇ Surface water monitoring
◇ Aquaculture water bodies
◇ Urban sewage treatment
◇ Industrial wastewater treatment
◇ Aquarium

 

 

FAQ
1. Which sensors can be connected to your dissolved oxygen controller?
A: The dissolved oxygen meter can be compatible with DRFN digital dissolved oxygen sensors including fluorescence and polarography.

 

2. How does your DO controller collect sensor data?
A: The connected sensor uploads the detected data in a special encrypted communication method to ensure that the DUC controller can collect high-precision data more stably

 

3. What are the applications of dissolved oxygen analyzers?
A: Sewage/Surface water monitoring/Aquaculture water bodies/Urban sewage treatment/Industrial wastewater treatment /Aquariums

 

Contact Details
Suzhou Delfino Environmental Technology Co., Ltd.

Contact Person: Yuki Fu

Tel: +8615716217387

Send your inquiry directly to us (0 / 3000)